Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD022EL43A
3HP 480V Delta VFD022EL43A Three-Phase Variable Frequency Drive
Manufacturer: Delta
Product No.: VFD022EL43A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The VFD022EL43A is a rugged, highly efficient micro-type AC motor drive engineered within Delta’s high-performance VFD-EL Series. Built specifically to optimize medium-duty 3-phase applications, this 3 HP (2.2 kW) variable frequency inverter provides stable velocity modulation for demanding automation equipment like commercial mixers, automated pumps, material conveyors, and exhaust fans. It operates smoothly on a 3-phase 380 to 480 V AC input line, delivering a steady 5.5 A output. Utilizing a highly compact Frame B footprint and a lightweight structure weighing only 1.5 kg (3.31 lbs), it delivers high power density for dense electrical enclosure lay-outs.
Core Technical Advantages
Optimized Frame B Footprint
The specialized Frame B housing maintains a narrow width of just 3.94 inches, allowing high-density side-by-side configurations on standard DIN rails. This compact geometry drastically cuts panel space requirements while supporting an upgraded 3 HP power delivery.
Flexible Braking Architectures
The drive integrates a native dynamic braking transistor combined with high-performance DC Injection braking control. This combination allows the inverter to halt high-inertia loads rapidly and safely, providing exceptional cycle precision across intermittent assembly lines.
High-Speed Scalar Performance
Supporting an adjustable output frequency up to 600 Hz, the open-loop V/Hz (Scalar) control system ensures accurate torque compensation and smooth speed curves for high-speed spindles and specialized manufacturing machinery.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD-EL Series) |
| Model Number | VFD022EL43A |
| Motor Power Rating | 3.0 HP / 2.2 kW |
| Rated Output Amps (CT) | 5.5 Amps |
| Nominal Input VAC | 480 Volts AC (Accepts 380–480 V) |
| Input Phase | 3-Phase |
| Device Net Weight | 1.5 kg (3.31 lbs) |
| Enclosure Rating | IP20 |
| Dimensions (H × W × D) | 6.85 × 3.94 × 5.35 Inches |
Installation and Maintenance
Enclosure Thermal Layouts
The IP20 open-type chassis must sit within a clean, climate-controlled cabinet environment free from oil mist, moisture, and conductive metal shavings. Keep a minimum vertical clearance of 50 mm above and below the Frame B module to allow heat from the cooling fans to escape properly.
Power Integration Rules
Terminate incoming 3-phase mains wires exclusively to input terminals R, S, T. Wire the motor leads directly to terminals U, V, W. Never introduce utility AC lines to the U, V, W outputs, or the internal power semiconductor components will suffer irreversible catastrophic failure.
Dynamic Braking Setup
For operations involving abrupt stops or vertical overhauling loads, connect an external braking resistor across the specialized internal braking block terminals. This prevents internal DC bus overvoltage faults ($OV$) from tripping the system off-line during sudden ramp changes.
Engineering Advantages
Onboard Operator Controls
The built-in human-machine interface includes a clear digital parameter screen and an indexed programming dial. This allows plant electricians to modify speed curves, monitor running amperage, and pull historical fault logs directly on the shop floor without secondary service computers.
Streamlined V/Hz Regulation
By optimizing high-demand open-loop scalar algorithms, this drive offers automatic torque boosting, multi-step operations, and integrated electronic thermal protection without the high cost overhead of advanced vector-drive systems.
Active Circuit Defense
Onboard firmware elements actively check for overcurrent, overvoltage, low input voltage, and ground leaks. If a fault is found, the inverter trips instantly to protect both the internal electronic components and the motor winding insulation.
Technical FAQs
Q1: What is the main structural difference between Frame A models and this Frame B module?
A1: Frame B units handle higher continuous current loads (up to 5.5 A) and feature a wider physical package (3.94 inches vs. 2.83 inches) along with a larger cooling fan assembly to manage the extra heat generated by 3 HP motor loads.
Q2: Can this 3-phase drive be run temporarily on a single-phase AC input supply?
A2: No. Operating this model on single-phase lines will cause rapid overheating of the input rectifier bridge and uneven strain on the DC bus capacitors. The system will safely trip on an input phase loss fault ($PHL$) to prevent hardware failure.
Q3: How do I avoid acceleration stall faults when running heavy conveyor loads?
A3: If the drive trips on overcurrent or stalls at startup, increase the acceleration time parameter ($ACC$) to give the drive more time to ramp up, or fine-tune the auto-torque boost configuration to supply more voltage at low speeds.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
-
How Does ABB Omni-Measurement Eliminate Process Safety Blind Spots?
ABB Omni-Measurement closes process safety blind spots using predictive analytics and cross-validated sensing. Real r...