Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:CI862
3BUA000037R1 ABB CI862 Communication Module Master
Manufacturer: ABB
Product No.: CI862
Product Type: Communication Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The ABB CI862 (Article Number: 3BUA000037R1) is a high-performance communication interface module designed for the AC 800M controller series. This module specifically enables the integration of TRIO and Genius I/O systems into the modern 800xA control environment. By acting as a specialized master on the CEX-Bus, the CI862 provides a reliable migration path for legacy installations, allowing users to leverage advanced controller features while maintaining their existing field I/O infrastructure.
Technical Configuration
TRIO/Genius I/O Communication
The CI862 3BUA000037R1 is engineered to operate exclusively in Master mode. It manages the cyclic data exchange between the AC 800M processor and Genius I/O blocks or TRIO racks. This interface ensures high-speed synchronization and robust data integrity, making it a critical component for plants that rely on TRIO bus technology for remote field distribution.
CEX-Bus Scalability
As a CEX-Bus module, the CI862 mounts directly to the side of the AC 800M controller or on a CEX-Bus expansion unit. Its compact design allows for multiple communication interfaces to be housed in a single rack, providing the flexibility needed to handle complex, multi-protocol industrial networks without expanding the cabinet footprint significantly.
Reliability and Lifecycle Status
Currently designated with a "Classic" lifecycle status, the 3BUA000037R1 remains a vital spare part and expansion module for established industrial sites. It is built to withstand demanding storage and operating conditions, featuring a wide storage temperature range and high tolerance for non-condensing humidity, ensuring long-term hardware availability for critical infrastructure.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model Number | CI862 3BUA000037R1 |
| Manufacturer | ABB |
| Series | AC 800M |
| Communication Protocol | TRIO / Genius I/O |
| Operational Mode | Master |
| Operating Humidity | 5% to 95% (Non-condensing) |
| Storage Temperature | -40°C to +70°C |
| Lifecycle Status | Classic |
| Weight | 0.7 kg (1.5 lbs) |
| Compliance | CE-marked, WEEE Directive |
Installation & Maintenance Guide
Module Mounting
The CI862 3BUA000037R1 should be installed on the CEX-Bus with the controller powered down unless the specific baseplate supports hot-swap procedures. Proper grounding of the CEX-Bus and the TRIO network cable shield is essential to prevent electromagnetic interference from affecting signal quality.
Network Configuration
Configuration of the Genius/TRIO network is performed through the ABB Engineering Suite. Engineers must define the baud rate and device addresses within the control software to match the physical hardware settings of the field I/O blocks to ensure successful communication established by the master module.
Engineering Advantages
Seamless Legacy Integration
The primary advantage of the CI862 is its ability to bridge the gap between legacy TRIO I/O hardware and the contemporary AC 800M control logic. This eliminates the need for full system "rip-and-replace" upgrades, allowing for incremental modernization that minimizes downtime and capital expenditure.
Standardized Compliance
Adhering to CE marking and the WEEE Directive 2012/19/EU, the module meets stringent European safety and environmental standards. This compliance ensures that the hardware is suitable for global deployment in regulated industries, including power generation, water treatment, and chemical processing.
Technical FAQs
Q1: Can the CI862 be used as a Slave device?
A1: No, the 3BUA000037R1 is designed to operate strictly in Master mode to control the TRIO/Genius I/O bus.
Q2: What is the significance of the "Classic" lifecycle status?
A2: "Classic" status means the product is no longer in active volume production but is fully supported with spare parts, maintenance, and technical assistance by ABB.
Q3: Is there a specific mounting orientation required?
A3: The module should be mounted vertically on a standard DIN rail via the AC 800M CEX-Bus base to ensure optimal heat dissipation and secure electrical connection.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...