Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:330903-00-21-10-02-05
330903-00-21-10-02-05 Bently Nevada Proximity Probe 210mm
Manufacturer: Bently Nevada
Product No.: 330903-00-21-10-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Bently Nevada 330903-00-21-10-02-05 3300 NSv Proximity Probe
Bently Nevada 330903-00-21-10-02-05 is a 3300 NSv proximity probe with M8x1 thread, without armor. Features 210mm overall case length, 1.0 meter total length, and miniature coaxial ClickLoc connector with standard cable. Multiple agency approvals included. Compatible and interchangeable with previous 3300 RAM probes. Weight: 0.11 kg (0.24 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Bently Nevada |
| Model | 330903-00-21-10-02-05 |
| Probe Type | 3300 NSv Proximity Probe, M8x1 thread, without armor |
| Unthreaded Length | 00 mm |
| Overall Case Length | 210 mm |
| Total Length | 1.0 meter (39 inches) |
| Connector Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approval | Multiple Approvals (Option 05) |
| Weight | 0.11 kg (0.24 lbs) |
| Probe DC Resistance (1.0m) | 4.2 ± 0.5 ohms |
| Linear Range | 1.5 mm (60 mils) from 0.25 to 1.75 mm |
| Recommended Gap Setting | 1.0 mm (40 mils) |
| Incremental Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit Line | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz with 305m field wiring |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 304 stainless steel |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Storage Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 inch) |
| Recommended Torque | Finger tight, max 0.56 N·m (5 in·lb) |
| Minimum Target Diameter | 8.9 mm (0.35 inch) |
Extension Cable Specifications
| Parameter | Specification |
| Center Conductor DC Resistance | 0.220 Ω/m (0.067 Ω/ft) |
| Shield DC Resistance | 0.066 Ω/m (0.020 Ω/ft) |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
| Maximum Field Wiring Length | 305 meters (1,000 feet) |
Key Features
- Mechanically and electrically compatible with previous 3300 RAM probes
- Increased chemical resistance for process compressor applications
- Superior side-view characteristics compared to 3000-series 190 probe
- Viton O-ring seals differential pressure between probe tip and case
- 75 ohm coaxial FEP insulated cable available in 0.5, 1, 5, or 7 meter lengths
- Field wiring supports 16 to 24 AWG with three-conductor shielded triad cable
Installation Guidelines
Probe Case Torque: Maximum rated torque for M8x1 probe cases is 7.3 N·m (65 in·lb). Recommended torque is 5.1 N·m (45 in·lb). Maximum thread engagement length is 12 mm.
Connector Torque: Finger tight maximum. Do not exceed 0.56 N·m (5 in·lb).
Minimum Bend Radius: 25.4 mm (1.0 inch) with or without stainless steel armor.
Gap Setting: Recommended gap is 1.0 mm (40 mils). Linear range begins at approximately 0.25 mm (10 mils) from target.
FAQs
Q1. Is the 330903-00-21-10-02-05 compatible with existing 3300 RAM systems?
A1. Yes. The 3300 NSv probe and extension cable are mechanically and electrically compatible and interchangeable with Bently Nevada's previous 3300 RAM proximity probe and extension cable.
Q2. What is the maximum field wiring distance from Proximitor Sensor to monitor?
A2. Maximum length is 305 meters (1,000 feet) between the 3300 XL NSv Proximitor Sensor and the monitor. Frequency response remains 0 to 10 kHz with this length.
Q3. Are the probes pressure tested before shipment?
A3. No. Probes are not pressure tested prior to shipment. The sealing material consists of a Viton O-ring. Contact the custom design department if pressure seal testing is required for your application.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Collaborative DCS Cut Load Response Delays Below 0.4 Seconds?
This paper presents a hierarchical DCS architecture for multi-unit collaborative control in thermal power stations. F...
-
How to Stop PLC Failure from Cabinet Heat?
This article reveals how hidden heat inside control cabinets causes 68% of random automation faults, compares MTBF be...
-
Can PLC Rewriting Replace Full Hardware Retrofit?
This article explains how cross-brand PLC code migration replaces full hardware replacement for legacy production lin...
-
Can Emerson Fix ISO 50001 Data Gaps in Old Factories?
This article explains why conventional PLC and DCS systems lack granular energy monitoring for ISO 50001 compliance. ...
-
Why does PLC signal interference cause 61% of shutdowns?
Heavy-duty lines have 3.2x more control faults than assembly lines due to EMI and load shocks. Standard PLCs cannot a...
-
What Is the Verified ROI of Cloud Automation?
Global manufacturers face scattered sites and limited maintenance staff. This article presents verified field data fr...