Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:22B-A2P3F104
22B-A2P3F104 PowerFlex 40P 2.3A Single-Phase VFD Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 22B-A2P3F104
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 4763g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
PowerFlex 40P Adjustable Frequency AC Drive
Allen-Bradley 22B-A2P3F104 delivers reliable motor control for single-phase applications. This 0.5 HP drive operates on 240V AC input. It provides 2.3A output current for small machinery and conveyors.
Key Specifications
- Brand: Allen-Bradley.
- Model: 22B-A2P3F104.
- Voltage: 240V AC, single-phase.
- Output Current: 2.3 A.
- Power Rating: 0.5 HP (0.4 kW).
- Frequency: 50/60 Hz input.
I/O & Communication
- Digital Inputs: 6 programmable terminals.
- Analog Inputs: 2 channels (0-10V, 4-20mA).
- Analog Outputs: 2 channels (0-10V or 4-20mA).
- Relay Outputs: 1 Form C relay (N.O./N.C.).
- Communication: RS-485 port for Modbus RTU.
- Input Method: Built-in keypad with local control.
Environmental & Installation
- Operating Temp: 0°C to 60°C (32°F to 140°F).
- Humidity: 5% to 95% non-condensing.
- Enclosure: Flange mount, IP20, NEMA/UL Open Type.
- Filter: No CE-compliant filter (requires external).
- Mounting: Panel or enclosure using flange kit.
Dimensions & Weight
- Height: 200 mm (7.87 in).
- Width: 85 mm (3.35 in).
- Depth: 140 mm (5.51 in).
- Weight: 4.763 kg (10.5 lb).
Package & Shipping
- Includes: One Allen-Bradley 22B-A2P3F104 drive.
- Delivery: FedEx, UPS, or DHL.
- Status: In stock.
- Payment: T/T, Western Union.
FAQ
-
Q: Does this drive support single-phase input?
A: Yes. 22B-A2P3F104 accepts 240V AC single-phase input only. Do not connect to three-phase supply. -
Q: What is the maximum cable length?
A: Unshielded motor cable up to 30m. Shielded cable up to 15m. Keep control wiring separate from power wiring. -
Q: Is an external filter required for CE compliance?
A: Yes. This drive has no internal CE filter. Add an external filter for CE-marked installations.
Resource
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...
