Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1756-L82EK
1756-L82EK 5MB EtherNet/IP Processor Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 1756-L82EK
Product Type: Controller Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 390g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley ControlLogix 1756-L82EK Overview
The Allen-Bradley 1756-L82EK is a high-performance central processing module belonging to the ControlLogix Logix5580 controller family. Engineered by Rockwell Automation, this standard processor is custom-built to handle the data-intensive workloads of advanced, high-speed industrial automation applications. It installs seamlessly into any standard ControlLogix 1756 chassis slot, leveraging an enhanced architecture that significantly accelerates processing cycles and system communications. As a designated "K" variant, this unit features a specialized, factory-applied conformal coating across its internal circuit board assemblies. This defensive layer shields sensitive electronics from harsh environmental airborne contaminants, moisture, and corrosive gas mixtures. Equipped with an onboard 1 Gbps Ethernet interface and a local USB 2.0 connection, the 1756-L82EK provides a centralized, ultra-responsive control hub with a net assembly weight of 0.39 Kilograms (approximately 0.86 Pounds), making it an ideal choice for modern smart-factory architectures, material handling systems, and heavy process manufacturing lines.
Technical Specifications Table
| Technical Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Controller Generation | ControlLogix Logix5580 Series |
| Catalog Part Number | 1756-L82EK |
| User Memory Capacity | 5 Megabytes (MB) fixed logic space |
| Environmental Protection | Conformally Coated PCB Insulation ("K" designation) |
| Onboard Interfaces | 1 Embedded Gigabit Ethernet Port (RJ45); 1 USB 2.0 Port (Type-B) |
| EtherNet/IP Node Limit | Up to 80 network devices/nodes maximum |
| Maximum I/O Capacity | 128,000 Digital I/O points; 4,000 Analog I/O points |
| Unsecured HMI Messaging | Up to 2,000 messages per second max. |
| Fully Encrypted HMI Messaging | 900 messages per second (Full Integrity & Confidentiality) |
| Continuous Power Dissipation | 6.2 Watts (W) |
| Thermal Dissipation Rating | 21.2 BTU per hour (BTU/hr) |
| Backplane Current (1.2V DC) | 5.0 milliamps (mA) |
| Backplane Current (5.1V DC) | 1.20 Amps (A) |
| Local Diagnostics Display | 4-character alphanumeric scrolling LED panel |
| Programming Environment | Studio 5000 Logix Designer Application Suite |
| Module Net Weight | 0.39 Kilograms (kg) / 0.86 Pounds (lbs) |
Installation, Hardware Routing, & Commissioning
Mechanical Layout and Slot Installation Mechanics
The 1756-L82EK processor features a standard single-slot hardware profile that mounts directly into any available slot on a standard ControlLogix 1756 I/O chassis. Despite its internal hardware improvements, the unit maintains a lightweight form factor of 0.39 Kilograms, preventing structural stress on the backplane connector lines. Prior to slotting the unit, ensure that the main power supply feeding the backplane chassis is completely shut down and locked out. Align the top and bottom integrated circuit guide tabs with the track rails inside the chassis. Push the module firmly straight back into the rack until the upper and lower locking tabs snap down securely into the metal frame, guaranteeing a uniform physical connection with the backplane logic pins.
Electrical Current Draw and Thermal Venting Limits
When engineering the power profile for your ControlLogix system, remember that the 1756-L82EK processor places a noticeable continuous current demand on the backplane logic lines. It draws 5.0 mA at 1.2V DC and a much more pronounced 1.20 Amps at 5.1V DC. Ensure that your slot-mounted 1756 power supply module has enough structural amperage headroom to comfortably back this controller plus the concurrent load of all neighboring communications cards and I/O blocks. Maintain clean, unobstructed ventilation airflow above and below the chassis to safely carry away the unit's 21.2 BTU/hr thermal dissipation footprint.
Network Cabling and System Commissioning
Field commissioning is straightforward using the built-in communication paths on the processor's front face. Insert a high-quality network cable directly into the integrated gigabit Ethernet port to link the device upward into your plant's industrial network infrastructure. For local engineering tasks, initial configuration, or firmware flashing via Studio 5000 Logix Designer, use a high-speed Type-B USB 2.0 patch cable connected into the front-facing service port. Once powered up, monitor the 4-character alpha/numeric scrolling LED readout to verify normal startup scripts and catch real-time system faults.
Frequently Asked Questions (FAQs)
Q1: What specific environmental hazards does the conformal coating on the "K" model protect against?
A1: The conformal coating on the 1756-L82EK is a thin polymeric film sprayed onto the circuit boards. It insulates against conductive dust settling across trace lines, prevents corrosion from high humidity or moisture sprays, and guards against trace degrading from caustic chemical gases. This makes the "K" model ideal for harsh locations like wastewater plants, paper mills, and petrochemical facilities.
Q2: Why does implementing higher levels of CIP Security lower the HMI messaging speeds?
A2: CIP Security forces the controller to use cryptographic handshakes, compute packet digital signatures, and decrypt incoming data frames. While basic operation allows up to 2,000 messages/sec, full confidentiality requires the internal processors to dedicate cycles to real-time math encryption, lowering the throughput capacity to 900 messages/sec.
Q3: Does the 1756-L82EK require an external battery card to maintain its logic program if power is lost?
A3: No. The ControlLogix Logix5580 processor line uses a built-in, non-volatile energy storage module. During a sudden power loss, this onboard capacitor circuit delivers enough energy to flush the temporary application memory directly into flash storage, eliminating the need to track, inspect, or swap out physical batteries.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Proper Warehousing Cut Automation Hardware Failures 80%?
This technical guide presents quantified storage and maintenance standards for industrial PLC, DCS, and TSI spare par...
-
Can Industrial Control Upgrades Cut Unplanned Downtime by 90%?
This article examines why legacy PLC, DCS, and vibration monitoring systems demand urgent retrofit in 2026. Citing re...
-
How to streamline industrial automation spare parts import clearance?
This guide delivers a data-driven framework for sourcing and clearing industrial automation spare parts, covering PLC...
-
How Fast Must DCS Switchover Be to Prevent Costly Process Upsets?
This article presents quantified DCS redundancy strategies using real 2024–2025 plant data. It details sub-100ms swit...
-
Why Is Explosion-Proof DCS Critical for Chemical Plant Safety?
This technical article examines how optimized multi-vendor explosion-proof DCS architectures address critical safety ...
-
How to restore Allen‑Bradley PLCs to 99.8% performance?
This technical article presents new, factory-original industrial automation hardware solutions for power plants and p...
