Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1746-P3
1746-P3 | Allen-Bradley SLC 500 DC Power Supply 24V 3.6A
Manufacturer: Allen-Bradley
Product No.: 1746-P3
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Allen-Bradley 1746-P3 SLC 500 DC Power Supply
Product Overview
The Allen-Bradley 1746-P3 is a DC power supply module for the SLC 500 controller platform. It operates at 19.2-28.8 VDC input and provides backplane power of 3.6 A at 5Vdc and 0.87 A at 24Vdc. Mounted at the left-most position of the chassis without occupying a slot, this module is certified for Class 1 Division 2 hazardous locations. Weight is 1.1 kg (2.5 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Allen-Bradley / Rockwell Automation |
| Model | 1746-P3 |
| Series | SLC 500 |
| Module Type | Power Supply |
| Input Voltage Range | 19.2-28.8 VDC |
| Nominal Input Voltage | 24 VDC |
| Input Power | 61 W |
| Typical Line Power | 90 VA |
| Inrush Current | 20 A |
| Current Capacity (5V) | 3.6 A |
| Current Capacity (24V) | 0.87 A |
| Backplane Current (5V) | 3.6 A |
| Backplane Current (24V) | 0.87 A |
| Hold-up Time (Full Load) | 5 ms |
| Hold-up Time (No Load) | 1000 ms |
| Isolation Voltage | 600V AC RMS for 1s (Version B+) |
| Fuse Protection | 1746-F3 or equivalent |
| Operating Temperature | 0 to 60 °C (32 to 140 °F) |
| Deration | 5% above 55 °C |
| Location | Left-most, 1746 Chassis |
| Dimensions (W x D x H) | 79.2 x 144.8 x 139.7 mm |
| Weight | 1.1 kg (2.5 lbs) |
Key Features
- Provides backplane power to SLC 500 chassis modules
- 19.2-28.8 VDC input with 24 VDC nominal
- 3.6 A at 5Vdc and 0.87 A at 24Vdc current capacity
- Mounted at left-most position, no chassis slot required
- 5 ms hold-up time at full load, 1000 ms at no load
- UL and C-UL Listed for Class 1 Div 2 hazardous locations
- 600V AC RMS isolation (Version B and later)
- Replaceable fuse (1746-F3 or equivalent)
- Designed for altitudes up to 2000 meters without derating
- Pollution Degree 2 and Category II rated
Installation Notes
Mount the power supply at the left-most position of the 1746 chassis. Use 1746-F3 fuse or equivalent (BUSSMAN AGC 5 or Nagasawa ULCS-61ML-5). Only 1/8 inch flat head and 1/4 inch Phillips head screwdrivers are required for installation. Observe ESD precautions: keep in static-shield packaging when not in use, avoid touching connector pins or circuit components.
FAQs
Q1: What is the input voltage range for the 1746-P3?
A1: 19.2-28.8 VDC with 24 VDC nominal.
Q2: What is the hold-up time at full load?
A2: 5 ms at full load, 1000 ms at no load.
Q3: Is this module certified for hazardous locations?
A3: Yes. UL and C-UL Listed for Class 1, Division 2, Groups A, B, C, D Hazardous Locations.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does ABB 800xA Unify Multi-Vendor Automation?
ABB Ability System 800xA unifies multi-vendor PLC and DCS hardware into one automation platform, consolidating p...
-
Why Do Pharma Plants Need Honeywell Batch Control for DCS?
Honeywell batch control built on ISA-88 and Experion DCS helps pharmaceutical manufacturers eliminate manual recipe e...
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...