Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1715-TADOF8
1715-TADOF8 Allen-Bradley Redundant Analog Output Base
Manufacturer: Allen-Bradley
Product No.: 1715-TADOF8
Product Type: Termination Assembly
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1715-TADOF8 is a specialized Duplex Analog Output Termination Assembly (TA) within the Bulletin 1715 redundant I/O product line. This assembly provides the critical physical interface for 1715-OF8 analog output modules, enabling redundant, fault-tolerant configurations in mission-critical process automation. With a lightweight design of only 0.15 kg, it allows for high-density mounting without compromising cabinet structural integrity. By supporting duplex module mounting, this unit ensures that signal delivery to field actuators remains uninterrupted, even in the event of a single module failure.
Core Technical Advantages
This termination assembly is built to support high-availability control strategies. It manages an output range of 0 to 24 mA per channel, providing versatile control for valves, actuators, and other current-driven field devices. The hardware is designed for robust field-side performance, featuring shielded signal ports and a category 2 wiring rating to minimize electromagnetic interference. With its 500V AC isolation test rating and support for 18–32V DC field power, the assembly provides a stable and secure connection point between the control logic and the industrial process.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Part Number | 1715-TADOF8 |
| Type | Duplex Analog Output TA |
| Channels | 8 Analog Outputs |
| I/O Range | 0...24 mA per channel |
| Power Dissipation | 3.6 W (System Max) |
| Weight | 0.15 kg (150 grams) |
| Dimensions | 4.2 cm x 13.2 cm |
Installation & Engineering Guide
For successful deployment, the termination assembly must be mounted within a suitable protective enclosure, as it is an open-style component. Use copper wiring rated for at least 85°C (185°F) and ensure the screw terminals are torqued to exactly 0.5 N-m to maintain electrical contact under industrial vibration. Because this is a redundant duplex assembly, engineers should populate both module slots with 1715-OF8 units to achieve full fault tolerance. Ensure that shielded cables are used for all 8 channels to comply with Category 2 noise immunity standards.
Engineering Advantages
The system eliminates single points of failure at the I/O termination level. Its design allows for "Hot Swap" capability when used with redundant 1715-OF8 modules, meaning a faulty module can be replaced while the remaining module continues to drive the field process. This capability is essential for industries like oil and gas or power generation, where a signal interruption could lead to significant safety risks or financial losses. Its slim 4.2 cm width allows for high-density mounting in standard control cabinets.
Technical FAQs
Q1: What modules are compatible with this termination assembly?
A1: This unit is specifically designed to support two 1715-OF8 8-channel analog output modules in a redundant (duplex) configuration.
Q2: Does this unit provide isolation between individual output channels?
A2: No. While the assembly provides 50V continuous basic insulation between the system and field side, there is no electrical isolation between the eight individual output ports.
Q3: What is the significance of the "Duplex" designation?
A3: Duplex means the termination assembly has two slots for two identical I/O modules. Both modules work in parallel; if one fails, the other maintains the output signal to the field device without interruption.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
-
Why Do Heavy Industries Trust GE Fanuc PLC and DCS Systems?
This article examines how GE Fanuc core components solve reliability gaps in heavy-load factory automation. It covers...
-
How Does Bently Nevada Predict Failures 180 Days in Advance?
Standard PLC and DCS systems often miss early vibration anomalies in rotating machinery, leading to 68% of sudden mec...
-
How Does ABB Omni-Measurement Eliminate Process Safety Blind Spots?
ABB Omni-Measurement closes process safety blind spots using predictive analytics and cross-validated sensing. Real r...