Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140DRC83000
140DRC83000 8 Output Module - Schneider
Manufacturer: Schneider
Product No.: 140DRC83000
Product Type: Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 475g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric Modicon Quantum 140DRC83000 8-Channel Relay Discrete Output Module
The 140DRC83000 is an 8-channel relay discrete output module from the Schneider Electric Modicon Quantum automation platform. This Form C (1 NO/NC) relay output module supports multiple voltage ranges and delivers up to 5A at 250/30V AC/DC resistive with 1250VA switching capacity.
Key Features
- 8 relay outputs with Form C (1 NO/NC) contacts
- Wide voltage range: 20-250V AC, 30-150V DC, 5-30V DC
- 5A maximum load current at 250/30V AC/DC resistive (60°C)
- 20A surge current capability for 10ms capacitive loads
- 1250VA resistive switching capacity
- Internal varistor overvoltage protection at 275V
- Marine certified: ABS, DNV, GL, RINA, RMRS
- 30 Hz switching frequency for resistive loads
Technical Specifications
- Brand: Schneider Electric
- Series: Modicon Quantum
- Model: 140DRC83000
- Product Type: Relay discrete output module
- Outputs: 8 discrete outputs
- Contact Type: 1 NO/NC (Form C)
- Output Voltage Range: 20-250V AC, 30-150V DC, 5-30V DC
- Maximum Load Current: 5A @ 250/30V AC/DC resistive (60°C)
- Surge Current: 20A for 10ms capacitive
- Switching Capacity: 1250 VA resistive
- Switching Frequency: 30 Hz resistive, F = 0.5/I²L inductive
- Response Time: 10ms (0 to 1), 20ms (1 to 0)
- Mechanical Durability: 10,000,000 cycles
- Electrical Durability: 200,000 cycles @ 5A 250V AC resistive
- Overvoltage Protection: Internal varistor, 275V
- Isolation: 1780Vrms AC for 1 minute / 2500V DC between channels and bus
- Power Dissipation: 2.75W + (0.5 x number of points on)
- Bus Current Requirement: 560 mA
- Module Format: Standard
- Net Weight: 0.3 kg (0.7 lb)
LED Indicators
- 8 green LEDs for individual output status
- 1 green LED (Active) for bus communication present
- 1 red LED (F) for external fault detection
Certifications & Standards
- Marine certifications: ABS, DNV, GL, RINA, RMRS
- FM Class 1 Division 2
- C-tick, GOST certified
- UL 508, CSA C22.2 No 142
- CE marked
Environmental Specifications
- Operating Temperature: 0 to 60°C (32 to 140°F)
- Storage Temperature: -40 to 85°C (-40 to 185°F)
- Relative Humidity: 95% without condensation
- Operating Altitude: up to 5000 m (16404 ft)
- Resistance to Electrostatic Discharge: 4 kV contact, 8 kV air (IEC 801-2)
- Resistance to Electromagnetic Fields: 9.1 V/m (10 V/m) 80-2000 MHz (IEC 801-3)
Package Includes
- 1x Schneider Electric 140DRC83000 relay output module
- Installation documentation
Package Dimensions
- Height: 16.3 cm (6.42 in)
- Width: 4.5 cm (1.77 in)
- Length: 31.2 cm (12.28 in)
- Package Weight: 475 g (16.8 oz)
Shipping
- FedEx, UPS, DHL express worldwide
- Ships within 24 hours from stock
- Ground shipping available
GTIN
3595861127081
FAQ
1. What is the part number for this relay module?
The part number is 140DRC83000.
2. How many outputs does the 140DRC83000 have?
It has 8 relay outputs with Form C (1 NO/NC) contacts and individual green LED indicators.
3. What is the maximum load current per output?
Each output can handle 5A at 250/30V AC/DC resistive at 60°C, with 20A surge current capability for 10ms.
Additional Specifications
- Gray
- Black
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...