Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IC697BEM734
IC697BEM734 GE 90-70 PLC Peer-to-Peer Datagram Module
Manufacturer: General Electric
Product No.: IC697BEM734
Product Type: Controller Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 1810g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The IC697BEM734 is a rugged, industrial Genius Bus Controller (GBC) manufactured by GE Fanuc for the Series 90-70 programmable logic controller (PLC) platform. Serving as an intelligent communication gateway, this single-slot module manages decentralized distributed networks utilizing Genius IC660 and IC661 input/output blocks. Weighing 1.81 kg, it offloads complex field communications from the central processing unit, facilitating deterministic peer-to-peer messaging, broad data acquisition, and real-time plant diagnostics across heavy-duty industrial automation applications.
Core Technical Advantages
-
Detailed Suffix Logic Breakdown:
- IC697: Establishes direct hardware form-factor alignment with the high-capacity GE Fanuc Series 90-70 VME rack.
- BEM: Identifies the module as a Bus Expansion Module purpose-built for field network coordination.
- 734: Represents the specific operational core and firmware iteration within the Genius interface line.
- Versatile Block Interfacing: Engineered specifically to act as a master communications link for legacy Genius IC660 and IC661 smart I/O blocks, safeguarding investments in existing field infrastructure.
- Flexible Baud Adjustments: Operates at a default transmission speed of 153.6 kbps, allowing tailored fieldbus configurations via system software to balance overall data throughput against physical network line distances.
- Advanced Datagram Messaging: Employs structured communication methodologies including Global data broadcasting, Directed control sequences, and Peer-to-Peer datagram configurations for efficient networking.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Number | IC697BEM734 |
| Bus Topology Protocol | Genius Bus System (IC660 / IC661 Block Networks) |
| Base Transmission Baud | 153.6 kbps default (fully user-configurable to alternative standard rates) |
| Hardware Node Address | Default Factory Address: 31 (software-reconfigurable via configuration utility) |
| Backplane Current Load | 1.3 Amps continuous continuous consumption drawn from the 5 V DC rail |
| Physical Interface Ports | PL1 port (Handheld Monitor alignment) | PL3 port (Genius Bus Field loop) |
| Diagnostic Array Layout | 3 physical LEDs indicating power status, active communication, and network fault |
| Climatic Thermal Range | –20°C to +60°C operational spectrum; 5% to 95% non-condensing relative humidity |
| Module Net Mass | Approximately 1.81 kg (4.0 lbs) heavy-duty industrial casing |
Installation & Maintenance Guide
Chassis Insertion and Seat Protocols
Ensure that all primary and auxiliary power to the Series 90-70 chassis rack is entirely switched off prior to handling. Align the card edge of the IC697BEM734 module with the physical tracking guides of any available rack slot. Push firmly until the backplane pins are completely seated, then tighten the upper and lower integrated chassis hardware screws to establish a path to earth ground.
Fieldbus and Handheld Tool Connection
Terminate the incoming industrial trunk line into the designated PL3 terminal connection block on the module faceplate. If field-level diagnostic sweeps or manual node configurations are required, connect an external Genius Handheld Monitor (HHM) directly into the dedicated PL1 diagnostic interface port without disrupting backplane transactions.
LED Operational State Awareness
Maintain continuous monitoring of the 3 integrated front-panel status LEDs to simplify system troubleshooting. The Power LED verifies stable backplane voltage delivery from the 5V rail. The Active LED flashes rhythmically to represent active datagram transmission across the Genius loop, while the Fault LED illuminates steady red to indicate an unaddressed communication timeout or local internal chip failure.
Engineering Advantages
- Stable Thermal Design: Built to endure extended industrial panel temperatures from –20°C to +60°C, preventing operational drift or communication dropouts under intense factory floor conditions.
- Independent Network Upgrades: Simplifies network optimization using specialized MS-DOS configuration scripts, allowing engineers to remap the default node address away from 31 without altering hardware components.
- Low System Footprint: Draws a stable 1.3 Amps at 5 V DC, keeping maximum power consumption below 6.5 Watts to minimize the heat generated inside sealed, unventilated enclosures.
- Highly Reliable Casing: Enclosed in a rugged 1.81 kg protective housing designed to insulate sensitive internal circuits from industrial electromagnetic interference (EMI) and ambient airborne dust.
Technical FAQs
Q1: Can this bus controller coexist with other network cards in the same Series 90-70 rack?
A1: Yes. The Series 90-70 VME platform supports multi-module configurations. You can install multiple IC697BEM734 controllers in a single chassis to build independent Genius field channels, provided the rack power supply has enough current capacity on the 5V DC rail.
Q2: Is the IC697BEM734 hot-swappable if a network chip component fails?
A2: No. The backplane design of the Series 90-70 PLC does not allow live hot-swapping. Removing or replacing the module while the rack is powered up can cause electrical arcs, corrupt active VME data traffic, and permanently damage the internal circuits of the module.
Q3: What cable types are recommended for connecting the PL3 field port to remote blocks?
A3: To maintain a stable 153.6 kbps transmission speed, use high-quality, low-capacitance shielded twisted-pair cables designed specifically for Genius networks. Ensure that appropriate end-of-line termination resistors match the characteristic impedance of the trunk to prevent signal reflections.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...