3500/60-01-00 Bently Nevada | Internal Terminations Unit
Manufacturer: Bently Nevada
Product No.: 3500/60-01-00
Product Type: Temperature Monitor
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Bently Nevada 3500/60-01-00 is a high-performance temperature monitor designed for continuous machinery protection. It accepts input from up to six Resistance Temperature Detectors (RTD) or Thermocouples (TC), providing critical thermal monitoring for rotating equipment like turbines, pumps, and motors. By converting sensor data into actionable alarms and proportional 4-20 mA signals, this module prevents catastrophic failure due to overheating and ensures long-term operational reliability.
Technical Configuration
The configuration for the 3500/60-01-00 model is defined as follows:
- I/O Module Type (01): RTD/TC Non-isolated I/O Module with Internal Terminations. This allows for direct field wiring to the back of the 3500 rack without external terminal blocks.
- Agency Approval (00): No specific hazardous area approvals selected (Standard Version).
Technical Specifications
| Parameter | Specification |
|---|---|
| Input Signal Count | 1 to 6 RTD or TC signals |
| Thermocouple Types | Type E, J, K, T |
| RTD Support | Platinum (100Ω), Nickel (120Ω), Copper (10Ω) |
| Analog Output | +4 to +20 mA per channel |
| Power Consumption | 7 Watts (Nominal) |
| Accuracy | ±3 °C at 25 °C (Standard Rack) |
| Rack Space | 1 Front Slot (Monitor), 1 Rear Slot (I/O) |
| Dimensions | 241.3 mm x 24.4 mm x 241.8 mm |
Engineering & Installation Guide
System Placement
The 3500/60 system consists of the main monitor module and a corresponding I/O module. The monitor fits into any full-height slot in the front of the 3500 rack, while the non-isolated I/O module must be installed in the same slot position on the rear of the rack.
Internal Termination Wiring
This module features internal terminations, allowing field wiring to connect directly to the I/O module. When using 3-wire or 4-wire RTDs, ensure that lead wire lengths are minimized or properly compensated in the software to maintain high measurement precision.
Alarm Delay & Logic
Alert and Danger setpoints are fully programmable via the 3500 rack configuration software. Users can set alarm time delays (1 to 60 seconds) to filter out transient thermal spikes, ensuring that trips only occur during sustained over-temperature conditions.
Engineering Advantages
Non-Contact & Precision Measurement
The 3500/60 offers high-impedance inputs (10 MΩ) and dedicated cold junction compensation for thermocouples, ensuring signal integrity even in electrically noisy industrial environments.
Real-time Visual Diagnostics
The front panel includes an OK LED to indicate module health, a TX/RX LED for communication status across the backplane, and a Bypass LED to warn operators when machinery protection is inactive during testing.
Comprehensive Recorder Function
Unlike basic sensors, the 3500/60 provides individual 4-20 mA outputs for every channel. These outputs are short-circuit protected and do not affect the monitor’s internal alarm logic if the recorder loop is compromised.
Technical FAQs
Q1: What is the difference between the 3500/60-01-00 and versions with an 01 or 02 suffix?
A1: The suffix "00" indicates that this module does not have specific ATEX/CSA hazardous area agency approvals. It is designed for use in standard industrial settings where these certifications are not required.
Q2: Does the module support 2-wire RTDs?
A2: While optimized for 3-wire and 4-wire RTDs to provide better accuracy, 2-wire RTDs can be used but may result in lower accuracy due to the lack of lead-wire resistance compensation.
Q3: Can I monitor different types of sensors on one module?
A3: Yes, the 3500/60 can simultaneously process signals from both RTDs and Thermocouples across its six channels, provided each channel is correctly configured in the 3500 software.
Aanvullende specificaties
- Wit
- Blauw
- Zilver
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...