Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IC693MDL940
IC693MDL940 24VDC/240VAC Output Module GE
Manufacturer: General Electric
Product No.: IC693MDL940
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The GE Fanuc IC693MDL940 is a high-performance relay output module designed for the Series 90-30 Programmable Logic Controller. It provides 16 discrete outputs, arranged in four isolated groups of four, allowing for the switching of different voltage sources within a single module. With a net weight of 0.4 kg (0.88 lbs), this unit offers a compact yet powerful interface for high-current industrial loads. It is engineered to handle both AC and DC voltages, making it a versatile choice for applications requiring mechanical contact isolation and high current-carrying capacity.
Core Technical Advantages
The IC693MDL940 is built for heavy-duty operation, supporting a maximum load of 2 Amps per output and a total module capacity of 16 Amps. This 0.4 kg module features a rapid response time of 15 ms for both "on" and "off" cycles, ensuring timely execution of control logic. To protect sensitive backplane electronics, the module provides 1500 VAC isolation for one minute between the field side and the logic side. Additionally, with its low power draw of only 7 mA from the 5V bus, it minimizes the thermal load on the PLC power supply even when all 16 relays are energized.
Technical Specifications
| Feature | Details |
|---|---|
| Brand | GE Fanuc (Emerson) |
| Model Number | IC693MDL940 |
| Outputs | 16 Points (4 Groups of 4) |
| Load Rating | 2 Amps per point (Max) |
| Unit Weight | 0.4 kg (0.88 lbs) |
| Operating Voltage | 5-250 VAC / 5-30 VDC |
Installation & Wiring Guidelines
When installing the GE Fanuc IC693MDL940, ensure the PLC rack power is disconnected before insertion. The 0.4 kg unit fits into any I/O slot of the Series 90-30 baseplate. Because the module can switch up to 250 VAC, users must adhere to local wiring codes, particularly regarding point-to-point isolation. The module supports a maximum common load of 4 Amps per group. It is recommended to use surge suppression (such as MOV or RC snubbers) when driving inductive loads to extend the mechanical life of the relay contacts and prevent EMI interference with adjacent modules.
Engineering Advantages
Engineers prefer the IC693MDL940 for its high-density relay count, which significantly reduces the number of modules required for large-scale output control. The mechanical relay design eliminates the leakage current issues found in Triac or Transistor modules, providing a "true open" state that is safer for certain maintenance procedures. Despite its 0.4 kg physical profile, the module is exceptionally rugged, capable of handling inrush currents up to 5 Amps. Its ability to switch mixed loads (AC and DC) within different groups makes it an incredibly flexible tool for modernizing legacy control systems.
Technical FAQs
Q1: What is the weight of the GE Fanuc IC693MDL940?
A1: This module has a net weight of 0.4 kg (0.88 lbs), reflecting its robust internal relay array and protective housing.
Q2: What is the minimum load requirement for the relays?
A2: To ensure reliable contact closing and prevent oxidation buildup, a minimum load of 10 mA is required for each output point.
Q3: Does the IC693MDL940 require an external power source?
A3: Yes, while the logic side is powered by the backplane, the relay coils require 135 mA from the 24V bus (typically provided by the PLC power supply) when all outputs are energized.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...