Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:IC693MDL931
IC693MDL931 GE Fanuc 8-Point NC Form C Relay Output
Manufacturer: General Electric
Product No.: IC693MDL931
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The GE Fanuc IC693MDL931 is an 8-point isolated relay output module designed for the Series 90-30 PLC environment. It is distinguished by its "Isolated" architecture, meaning each output point has its own common return, providing maximum electrical separation between channels. With a highly compact net weight of only 0.2 kg (0.44 lbs), this module delivers significant switching power. It supports Form C and NC relay contacts, making it suitable for applications that require normally closed logic or changeover capabilities for 24VDC or 120/240VAC loads.
Core Technical Advantages
The IC693MDL931 is built for high-capacity performance, featuring a maximum resistive load rating of 8 Amps per output. This 0.2 kg lightweight module offers professional-grade protection with a 1500 VAC isolation rating (for 1 minute) between field points and the PLC backplane. It consumes a mere 6 mA from the 5V bus, while the relay coils draw 110 mA from the 24V bus when fully energized. Its rapid response time of 15 ms and low leakage current (1 mA max) ensure precise and reliable operation for safety-interlock systems and motor starter control.
Technical Specifications
| Feature | Details |
|---|---|
| Brand | GE Fanuc (Emerson / Rockwell Automation) |
| Model Number | IC693MDL931 |
| Output Points | 8 (Fully Isolated) |
| Max Resistive Load | 8 Amps per point |
| Unit Weight | 0.2 kg (0.44 lbs) |
| Voltage Range | 5-250 VAC / 5-30 VDC |
Installation & Thermal Management
Installation of the GE Fanuc IC693MDL931 is seamless within any Series 90-30 I/O slot. Despite its 0.2 kg frame, the module can carry up to 20 Amps total for UL installations. It is crucial to monitor ambient temperature, as the total module current may require derating in hotter environments to prevent internal component fatigue. Wiring should account for the isolated nature of the points; because each output has an independent return, engineers can mix different power phases or DC sources across the eight channels without risk of cross-talk or short circuits.
Engineering Advantages
The IC693MDL931 is an engineer's choice for complex signaling where isolation is paramount. The 8A inrush current capacity allows it to handle the initial surge of inductive loads like solenoids or small contactors. The module's 0.2 kg design includes Form C relays, providing both a normally open and normally closed contact for each point, which is essential for "fail-safe" logic applications. Furthermore, the point-to-point isolation eliminates the need for external interposing relays in many scenarios, saving both cost and panel space while maintaining 250 VAC continuous isolation.
Technical FAQs
Q1: What is the physical weight of the GE Fanuc IC693MDL931?
A1: This module has a net weight of 0.2 kg (0.44 lbs), making it one of the lighter yet most robust relay modules in the Series 90-30 lineup.
Q2: What is the benefit of an "Isolated" relay module?
A2: Isolation allows each of the 8 relay outputs to operate with its own dedicated common, enabling you to switch different voltages or different phases on the same module safely.
Q3: Does the IC693MDL931 support high-speed switching?
A3: It has a response time of 15 ms for both On and Off states. While typical for mechanical relays, it is best suited for general control logic rather than high-speed pulse applications.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...
