Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:5094-OB16S
5094-OB16S Allen-Bradley Ple Cat 4 Digital Output Module
Manufacturer: Allen-Bradley
Product No.: 5094-OB16S
Product Type: Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The 5094-OB16S is a high-reliability, 16-channel digital sourcing safety output module from the advanced FLEX 5000 I/O platform engineered by Allen-Bradley (Rockwell Automation). Specifically architected for functional safety deployment within critical industrial automation networks, this premium hardware card delivers sixteen safety-rated sourcing outputs operating across an 18 to 32V DC range. Weighing a compact 0.2 kg (0.44 lbs), the module provides distributed safety control and automated diagnostic coverage directly at the machine layer, acting as a core protection node for machinery safety systems.
Core Technical Advantages
- High-Fidelity Safety Integrity: Attains rigorous global safety certifications up to SIL 3 (IEC 61508), Category 4 / PL e (ISO 13849-1), making it ideal for managing safety-critical emergency stops, light curtains, and safety interlocking perimeters.
- Rapid Safety Reaction Profile: Features an ultra-responsive, deterministic safety reaction time capped at a maximum of 4.5 ms, ensuring rapid de-energization of hazardous machinery zones when an override or fault condition triggers.
- Advanced Sourcing Output Design: Provides 16 independent sourcing channels rated at 0.5 Amperes per point, utilizing integrated solid-state pulse testing to continuously monitor field wiring lines for short circuits or cross-faults.
- Industrial Dielectric Boundary: Equipped with a robust 250V continuous isolation barrier that protects internal backplane logic components from dangerous high-voltage spikes, transient noise, or ground loop interference on the shop floor.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Catalog Number | 5094-OB16S |
| Product Line Platform | Allen-Bradley FLEX 5000 Safety I/O Platform |
| Functional Safety Rating | SIL 3 / Category 4 / Performance Level e (PL e) |
| Output Configuration | 16-Point Sourcing Safetey Outputs (Current Source to Load) |
| On-State Operating Voltage | 18 to 32V DC field power distribution window |
| Maximum Output Current | 0.5 Amperes maximum continuous load per individual point |
| Maximum Safety Reaction Time | 4.5 milliseconds absolute response threshold |
| Continuous Isolation Voltage | 250V continuous operational testing boundary barrier |
| Thermal Power Dissipation | 3.5 Watts maximum structural energy release |
| Physical Net Mass | 0.2 kg (approx. 0.44 lbs) hardware chassis |
Industrial Solutions
- Robotic Workcell Interlocking: Safeguards automated manufacturing cells by immediately cutting power to robotic arm tooling actuators whenever optoelectronic light curtains or safety gates are breached.
- Emergency Stop Arrays: Collects and processes localized hardwired E-stop loop buttons across vast packaging facilities, ensuring fail-safe equipment shutdowns under SIL 3 standards.
- High-Risk Material Converters: Controls heavy hydraulic safety valves and mechanical shear brakes, executing millisecond-accurate torque-off commands to prevent operator injury.
- Chemical Batching Security: Manages safety shutoff valves in explosive or dangerous fluid handling loops, operating reliably across harsh, volatile plant conditions.
Wiring & Installation
Upstream Power Isolation
Isolate and lock out all primary facility electrical links and secondary auxiliary 24V DC field power lines before handling the module. Working on live safety infrastructure can cause unintended safety trips, lead to localized short-circuits, or introduce corrupted diagnostic data into the active safety controller's memory.
Module Mounting and Seat Verification
Align the 5094-OB16S module with the keyway channels on your pre-installed FLEX 5000 terminal base mounting assembly. Push the module firmly onto the backplane track until the integrated retaining latch clicks home. Verify that the housing sits flush and square against the terminal base to guarantee steady, low-resistance electrical communication.
Field Safety Conductor Termination
Strip your field-side safety wiring conductors carefully to expose the underlying core. Insert copper wires (sized between 22 and 14 AWG) directly into the push-in terminal points, strictly matching your pre-engineered SIL 3 safety channel schematic. Sinking lines from your field actuators must trace back directly to the same master DC common ground rail.
Pulse Testing and Diagnostic Setup
Apply 24V DC field-side actuator power and boot up the GuardLogix control rack. When configuring the module within Studio 5000 Logix Designer, determine if your field devices require active pulse testing; these brief diagnostic pulses verify cable integrity and help identify short circuits or ground faults automatically without disrupting your actuators.
Engineering Advantages
- Seamless GuardLogix Syncing: Fully compatible with ControlLogix 5580S and CompactLogix 5380S safety controllers, making it easy to configure safety logic using standard safety function blocks.
- Integrated Smart Pulse Testing: Features onboard pulse-testing algorithms that scan for external wire-to-wire shorts, field cross-talk, and open-circuit states, preventing dangerous unmonitored faults.
- Studio 5000 Add-On Profiles: Leverages native software integration inside Studio 5000 Logix Designer, reducing engineering layout time and allowing you to adjust safety parameters online.
Technical FAQs
Q1: Why is a max 4.5 ms safety reaction time critical for a SIL 3 output module?
A1: In machinery safety applications, milliseconds save lives. A deterministic 4.5 ms reaction time guarantees that the moment a safety violation occurs, the module drops power almost instantly, helping you meet strict safety distance standards for hazardous machine parts.
Q2: Can I combine copper and aluminum wiring when connecting field devices to the 5094-OB16S?
A2: No. The terminal block clamps are rated strictly for 22 to 14 AWG copper wire. Mixing metals can trigger galvanic corrosion and cause loose connections over time, which compromises your safety loop and can lead to nuisance trips.
Q3: What does a sourcing safety output do if it detects an external short-circuit to ground?
A3: The 5094-OB16S uses smart solid-state switches that detect overcurrent states instantly. If an output wire shorts to ground, the module shuts down that specific channel immediately, signals a diagnostic fault to the main controller, and turns on a front-panel fault LED for easy troubleshooting.
Aanvullende specificaties
- Rood
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Makes 50ms Failover Critical for Industry 4.0 Smart Factories?
This article examines ABB DCS full-link redundancy design for pharmaceutical manufacturing under GMP and Industry 4.0...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...