Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:V18345-1010120001
TZIDC Positioner Single Acting | V18345-1010120001 ABB
Manufacturer: ABB
Product No.: V18345-1010120001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The V18345-1010120001 is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, and single-acting fail-safe output. Aluminum housing with IP65/NEMA 4X protection. Weight: 1.7 kg.
Technical Configuration
Control Characteristics
Signal 4–20 mA corresponds to actuator position 0–100%, freely selectable for split-range operation (min range 20% / 3.2 mA). Characteristic curve: linear, equal percentage 1:25/1:50 or 25:1/50:1, freely configurable with 20 reference points. Travel limit adjustable to 20% minimum.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1010120001 |
| Manufacturer | ABB |
| Type | TZIDC Electro-Pneumatic Positioner |
| Input Signal | 4–20 mA (two-wire), split-range selectable |
| Communication | HART, LKS local connector |
| Output / Safe Position | Single acting, fail safe |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 tap holes 1/2-14 NPT or M20 x 1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 0–5 V DC (logical 0), 11–30 V DC (logical 1) |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Ambient Temperature | -40°C to +85°C (operation/storage/transport) |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Characteristic Curve | Linear, equal percentage, freely configurable (20 points) |
| Travel Limit | 0–100%, min 20% |
| Shut-off Function | Separately settable per end position |
| Travel Time Prolongation | Settable per direction |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Do not expose screw terminals to strain.
Air Supply
Use instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption <0.03 kg/h independent of supply pressure.
Electrical Connection
Connect 4–20 mA two-wire signal. Cable entry: 2 tap holes 1/2-14 NPT or M20 x 1.5 (one with cable gland, one with pipe plug). HART communication via signal line.
Engineering Advantages
Precise Valve Control
Freely configurable characteristic curves with 20 reference points. Split-range operation down to 20% (3.2 mA). Separate shut-off function and travel time prolongation per direction for precise process control.
Robust Environmental Protection
IP65/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion. Operates from -40°C to +85°C with 95% humidity (condensation permissible). Suitable for demanding industrial environments.
Flexible Configuration
Single-acting fail-safe output ensures safe valve position on power loss. HART communication enables remote diagnostics. Travel limit adjustable within 0–100% (minimum 20%) for application flexibility.
Technical FAQs
Q1: What is the supply pressure range for this positioner?
A1: 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.
Q2: What is the fail-safe behavior on electrical power failure?
A2: The 1 suffix indicates single-acting, fail-safe output. The actuator moves to its safe position on loss of electrical power.
Q3: What ambient temperature range does this positioner support?
A3: -40°C to +85°C for operation, storage, and transport. When using proximity switches SJ2-S1N (NO), the range is -25°C to +85°C.
Ytterligere spesifikasjoner
- Sølv
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...