Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:6ES7455-0VS00-0AE0
Siemens 6ES7455-0VS00-0AE0 | S7-400 FM 455 C 16 AI/16 AO
Manufacturer: Siemens
Product No.: 6ES7455-0VS00-0AE0
Product Type: Control Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Siemens 6ES7455-0VS00-0AE0 is an FM 455 C control module for SIMATIC S7-400 systems, providing 16 continuous control channels. It combines 16 analog inputs, 16 digital inputs, and 16 analog outputs in a single module. Weighing approximately 1,400 g, this controller supports thermocouples, Pt100 resistance thermometers, and standard voltage/current signals for comprehensive process control.
Technical Configuration
This module operates from 24 V DC load voltage with a permissible range of 20.4 to 28.8 V. It draws a maximum of 440 mA (typical 370 mA) from load voltage without load. The 16 analog inputs accept thermocouples or 2-wire connections, while 8 channels support Pt100 or 4-wire connections. Integrated control technology provides 16 closed-loop controllers. Potential separation between channels and backplane bus uses optocouplers, tested at 500 V DC isolation.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6ES7455-0VS00-0AE0 |
| Product Type | FM 455 C Control Module |
| Series | SIMATIC S7-400 |
| Control Channels | 16 continuous |
| Load Voltage | 24 V DC (20.4-28.8 V) |
| Current from L+ (No Load) | Max 440 mA, typ. 370 mA |
| Power Loss | Typ. 12 W, max 17.3 W |
| Digital Inputs | 16, 24 V DC (IEC 61131 type 2) |
| DI Signal "0" / "1" | -3 to +5 V / 13 to 30 V (7 mA typical) |
| Analog Inputs | 16 (8 with Pt100/4-wire) |
| Voltage Input Ranges | 0 to +10 V, -1.75 to +11.75 V, -80 to +80 mV |
| Current Input Ranges | 0-20 mA, 0-23.5 mA, -3.5 to +23.5 mA, 4-20 mA |
| Thermocouple Types | B, J, K, R, S |
| RTD Type | Pt100 |
| Analog Outputs | 16 |
| Voltage Output Ranges | 0-10 V, -10 to +10 V |
| Current Output Ranges | 0-20 mA, -20 to +20 mA, 4-20 mA |
| Voltage Output Load | Min 1 kΩ, max 1 µF capacitive |
| Current Output Load | Max 500 Ω, max 1 mH inductive |
| Resolution | 12 or 14 bit, parameterizable |
| Settling Time | 0.1 ms resistive, 3.3 ms capacitive, 0.5 ms inductive |
| Closed-Loop Controllers | 16 |
| Isolation Tested | 500 V DC |
| Dimensions (W x H x D) | 50 x 290 x 210 mm |
| Weight | Approx. 1,400 g |
| Front Connector | 2 x 48-pin required |
Installation Guide
Install the FM 455 C module in a compatible S7-400 rack slot and secure both 48-pin front connectors. Connect 24 V DC load voltage within the 20.4-28.8 V range. Use shielded cable for analog signals with maximum 200 m length (50 m for 80 mV and thermocouple inputs). Verify voltage output loads meet minimum 1 kΩ and current output loads remain below 500 Ω. Internal or external Pt100 temperature compensation is parameterizable for thermocouple measurements.
Engineering Advantages
This module integrates 16 closed-loop controllers with 16 AI, 16 DI, and 16 AO in a single unit, reducing rack space and wiring. Support for thermocouples, Pt100 RTDs, and standard voltage/current signals provides exceptional measurement flexibility. Parameterizable 12-bit or 14-bit resolution suits both standard and high-precision applications. Optocoupler isolation between channels and backplane bus protects the system from field transients. Short-circuit-protected voltage outputs with 25 mA limit safeguard connected actuators.
Technical FAQs
Q1: How many control loops does the 6ES7455-0VS00-0AE0 support?
A1: This module integrates 16 closed-loop controllers with 16 analog inputs, 16 digital inputs, and 16 analog outputs.
Q2: What temperature sensor types does this module accept?
A2: It accepts thermocouple types B, J, K, R, and S, plus Pt100 resistance thermometers with parameterizable internal or external compensation.
Q3: What are the analog output load requirements?
A3: Voltage outputs require minimum 1 kΩ load (max 1 µF capacitive), while current outputs accept maximum 500 Ω load (max 1 mH inductive).
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does Siemens ET200SP Simplify PLC and DCS Integration?
This article explains Siemens ET200SP distributed remote I/O hardware sizing, DIN rail installation, field wirin...
-
How Do GE IC695 RX3i I/O Modules Work?
This article explains GE IC695 RX3i I/O module specifications, compatibility validation, field installation proc...
-
What Is Emerson DeltaV Virtual DCS and How Does It Work?
Emerson DeltaV Virtual DCS replicates full distributed control system behavior using identical runtime binaries, enab...
-
How to Commission Siemens PCS 7 OS for DCS Plants?
This article explains how to commission, troubleshoot and tune Siemens PCS 7 OS operator stations for distribute...
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...