Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:6ES7312-5BE03-0AB0
Siemens 6ES7312-5BE03-0AB0 CPU 312C Compact
Manufacturer: Siemens
Product No.: 6ES7312-5BE03-0AB0
Product Type: CPU Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 409g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
SIEMENS 6ES7312-5BE03-0AB0 SIMATIC S7-300 CPU 312C Compact CPU
The SIEMENS 6ES7312-5BE03-0AB0, also cataloged as the 6ES7312-5BE03-0AB0 CPU 312C, operates as a compact central processing unit with integrated digital I/O and fast counters executing user logic within SIMATIC S7-300 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7312-5BE03-0AB0 |
| Brand | Siemens |
| Product Type | CPU 312C Compact CPU Spare Part |
| Series | SIMATIC S7-300 |
| Hardware Product Version | 01 |
| Firmware Version | V2.6 |
| Programming Package | STEP 7 V5.3 SP2 or higher with HW update |
| Rated Supply Voltage | 24 VDC |
| Permissible Range | 20.4 V to 28.8 VDC |
| Current Consumption | 500 mA rated, 60 mA typ no-load |
| Inrush Current | 11 A typ, 0.7 A2s |
| Power Loss | 6 W typ. |
| Work Memory | 32 kbyte integrated, not expandable |
| Load Memory | MMC plug-in, max 4 Mbyte |
| Digital Inputs | 10 (8 usable for technological functions) |
| Digital Outputs | 6 (2 high-speed) |
| Fast Counters | 2 at 10 kHz |
| MPI Interface | 1 x RS 485, max 50 m without repeater |
| Front Connector | 1 x 40-pin |
| Dimensions (W x H x D) | 80 mm x 125 mm x 130 mm |
| Weight | 409 g (approx.) |
Integrated I/O and Counter Functions
Unit weight is approximately 409 g with dimensions of 80 mm width, 125 mm height, and 130 mm depth. The CPU 312C integrates 10 digital inputs and 6 digital outputs with a 24 VDC power supply. Two fast counters operate at 10 kHz for technological functions. Bit operations execute in 0.2 us typical, word operations in 0.4 us, fixed point arithmetic in 5 us, and floating point arithmetic in 6 us. Work memory is 32 kbyte and is not expandable; load memory requires a micro memory card with a maximum of 4 Mbyte. Data retention on the MMC is guaranteed for a minimum of 10 years without battery. A total of 1024 blocks (DB, FC, FB) are supported with a maximum size of 16 kbyte per block. The integrated MPI RS 485 interface supports cable lengths up to 50 m without a repeater. Reverse polarity protection is provided on digital inputs but not on digital outputs. Digital outputs are short-circuit protected with a typical response threshold of 1 A and support switching frequencies up to 100 Hz with resistive load, 2.5 kHz for pulse outputs.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7312-5BE03-0AB0?
A: Approximately 409 g, with dimensions of 80 mm width, 125 mm height, and 130 mm depth.
Q: What memory card does the CPU 312C require?
A: A micro memory card (MMC) is required. Maximum supported capacity is 4 Mbyte. The integrated 32 kbyte work memory is not expandable.
Q: How many fast counters does the CPU 312C support?
A: Two fast counters at 10 kHz for technological functions, with eight digital inputs usable for technological functions.
Field Installation Guidelines
Install the CPU in slot 2 of the S7-300 rail and secure the mounting screws. Verify 24 VDC supply polarity before energizing; digital inputs are reverse polarity protected, digital outputs are not. Insert a micro memory card before downloading the program. Confirm firmware version V2.6 matches the hardware update in STEP 7 V5.3 SP2 or higher. Route shielded encoder cables for technological functions to a maximum of 100 m; unshielded cables are not permitted for counter inputs. Verify MPI cable length does not exceed 50 m without a repeater. External power supply lines require a miniature circuit breaker type C at minimum 2 A or type B at minimum 4 A.
Ytterligere spesifikasjoner
- Svart
- DC-drevet
- Modulær
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Troubleshoot Allen-Bradley PLC and ABB DCS Commissioning Faults?
Joint commissioning of Allen-Bradley PLC and ABB DCS systems demands rigorous signal mapping, layered diagnostics, an...
-
What Causes Packet Loss in DeltaV and ABB Fieldbus Networks?
This article explains how to optimize communication between Emerson DeltaV DCS and ABB fieldbus control modules ...
-
How Does Allen-Bradley Redundant PLC Improve DCS Safety?
This article explains how Allen-Bradley redundant PLC deployment supports petrochemical DCS safety control. It covers...
-
Can Mixed-Vendor PLCs Unite Without Full Replacement?
ABB industrial Ethernet modules translate protocols across Allen-Bradley, Siemens, and ABB PLC platforms in brownfiel...
-
How Do You Troubleshoot GE Fanuc PSU Failures?
This guide explains how field engineers can detect, diagnose, and prevent GE Fanuc power supply failures in legacy fa...
-
How Does Bently Nevada Transducer Replacement Cut Fan Downtime?
This article explains how to replace Bently Nevada vibration transducers on centrifugal fans without disrupting plant...
