Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:TSXETG100
Schneider Electric TSXETG100 ConneXium Ethernet Gateway
Manufacturer: Schneider
Product No.: TSXETG100
Product Type: Ethernet Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 1360g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The TSXETG100 is a ConneXium Transparent Ready Ethernet Modbus gateway/router manufactured by Schneider Electric. Designed for seamless integration within TSX Micro PLC architectures and broader automation networks, this unit converts Modbus TCP/IP protocols to Modbus RTU/ASCII serial links. Operating on a rated supply voltage of 24 V DC (or via Power over Ethernet IEEE 802.3af), it supports serial communication across RS485 (57.6 kbps) and RS232 (38.4 kbps) connections. Housed in a compact IP30 DIN rail casing with a net unit weight of 1.36 kg (3.00 lbs), it features an embedded Class B10 web server for remote diagnostics and configuration.
Core Technical Advantages
- Dual Power Capability: Operates on standard 24 V DC external power or directly via Power over Ethernet (PoE IEEE 802.3af) for simplified field installation.
- Embedded Web Server (Class B10): Provides predefined HTML web pages for network diagnostics, device register reading/writing, and active Modbus list mapping without specialized software.
- Multi-Protocol Support & On-Board Security: Integrates Modbus TCP/IP, HTTP, FTP, SNMP, ARP, BOOTP, and FDR client protocols alongside an integrated miniature firewall for IP address filtering and password protection.
- High Serial Device Density: Connects up to 32 Modbus serial devices on a single RS485 multidrop network with selectable baud rates up to 57.6 kbps.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer / Brand | Schneider Electric |
| Product Line / Range | TSX Micro PLCs / ConneXium Series |
| Part Number / Catalog No. | TSXETG100 |
| UPC / GTIN | 785901524939 / 00785901524939 |
| Rated Supply Voltage | 24 V DC / Power over Ethernet (PoE IEEE 802.3af) |
| Ethernet Interface & Speed | RJ45 Port | 10BASE-T/100BASE-TX (10/100 Mbps) |
| Serial Connections & Speeds | RS485 (5-way removable terminal, 57.6 kbps) | RS232 (RJ45, 38.4 kbps) |
| Supported Protocols | Modbus TCP/IP, Modbus RTU/ASCII, HTTP, FTP, SNMP, ARP, BOOTP |
| Max Connected Serial Devices | Up to 32 devices on Modbus serial link |
| Physical Dimensions & Weight | 72 x 81 x 76 mm (2.8 x 3.2 x 3.0 in) | Net Weight: 1.36 kg (3.00 lbs) |
| Enclosure Rating & Mounting | IP30 | Symmetrical DIN Rail Mount |
| Operating Temperature & Humidity | 0 to 60 °C (32 to 140 °F) | 5 to 95 % RH (non-condensing) |
| Standards & Certifications | UL 508, CSA C22.2 No 14-M91, EN 61000-6-2, FCC Class A, CE, cUL, UL |
Engineering Installation & Guidelines
- Serial Switch Configuration: Adjust the hardware micro-switches located on the module to configure polarization and termination resistors for the RS485 serial link prior to powering on.
- Diagnostic LED Status Check: Utilize the 7 front-panel LEDs for troubleshooting—3 LEDs monitor RS485, RX, and TX for serial communication, and 4 LEDs indicate LK, RX, TX, and 100 Mbps Ethernet links.
- Network Security Setup: Access the predefined web server via standard browser to enable IP address filtering and assign protective passwords before connecting the gateway to plant networks.
Why Choose This Model
- Dual Power Flexibility: Runs on 24 V DC or standard PoE to simplify cabinet wiring.
- Compact DIN Rail Mount: Small 72 x 81 mm footprint saves space in control cabinets.
- Integrated Web Diagnostics: Embedded Class B10 server enables instant register access via web browser.
Technical FAQs
Q1: Does the TSXETG100 support Power over Ethernet (PoE)?
A1: Yes, it supports PoE IEEE 802.3af in addition to 24 V DC input.
Q2: How many devices can connect on the serial link?
A2: Up to 32 Modbus RTU/ASCII devices on the RS485 serial link.
Q3: What are the physical dimensions and weight?
A3: Measures 72 x 81 x 76 mm and weighs 1.36 kg (3.00 lbs).
Ytterligere spesifikasjoner
- Grå
- Sølv
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does ABB Fieldbus Cut Industrial Automation Wiring Costs?
ABB fieldbus instruments reduce cable costs by 40-55% and enable real-time DCS diagnostics, yet 62% of faults stem fr...
-
Can Wireless Gas Detection Fix Hard-to-Reach Plant Blind Spots?
This article reviews how the Honeywell Universal Transmitter enables wireless gas detection in hard-to-reach hazardou...
-
How Does GE Cimplicity HMI Tuning Boost Operator Performance?
This article explains how targeted GE Cimplicity HMI tuning improves operator performance in large control rooms. It ...
-
Why Do Continuous Process Plants Need ABB Redundant Networks?
This article examines practical ABB redundant control network design for continuous process plants, covering dual sta...
-
How Do You Install a Bently Nevada Keyphasor Sensor Correctly?
This article explains how to install and align a Bently Nevada keyphasor sensor for turbine TSI monitoring. It covers...
-
How Can You Tune GE Proficy Historian Compression?
This article explains how to tune GE Proficy Historian compression for industrial time-series archives, covering dead...