Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:KCD2-SOT-EX1.LB
KCD2-SOT-Ex1.LB Isolated Barrier | Pepperl+Fuchs
Manufacturer: Pepperl+Fuchs
Product No.: KCD2-SOT-EX1.LB
Product Type: Switch Amplifier
Product Origin: DE
Payment:T/T, Western Union
Weight: 100g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Pepperl+Fuchs KCD2-SOT-Ex1.LB Switch Amplifier
The Pepperl+Fuchs KCD2-SOT-Ex1.LB is an isolated switch amplifier for hazardous areas. This 1-channel barrier interfaces NAMUR sensors with control systems. It provides two transistor outputs for signal splitting applications. The Pepperl+Fuchs KCD2-SOT-Ex1.LB offers safe operation in explosive atmospheres with ATEX certification.
Product Identification
- Manufacturer: Pepperl+Fuchs
- Model Number: KCD2-SOT-Ex1.LB switch amplifier
- Product Type: 1-Channel Isolated Barrier
- Primary Function: Digital input signal conditioning
- Safety Rating: SIL 2, SC 3 per IEC/EN 61508
- Certification: ATEX certified for hazardous areas
- Housing Width: 12.5 mm compact design
Power Supply Specifications
- Supply Voltage: 24 V DC nominal (19-30 V DC range)
- Connection: Power Rail or terminals 9+, 10-
- Rated Current: 20-15 mA typical consumption
- Power Dissipation: ≤ 700 mW maximum
- Ripple Tolerance: ≤ 10 % input ripple
Input Specifications
- Signal Type: Digital Input (NAMUR or dry contact)
- Connection: Terminals 1+, 2- (field side)
- NAMUR Values: 10 V DC / 8 mA per EN 60947-5-6
- Switching Point: 1.2-2.1 mA with 0.2 mA hysteresis
- Line Fault Detection: Breakage I ≤ 0.1 mA, short I ≥ 6.5 mA
- Pulse Requirements: Min. 100 µs pulse/pause ratio
Output Performance
- Output Channels: Two passive transistor outputs
- Connection: Output I: terminals 5,6; Output II: terminals 7,8
- Rated Voltage: 30 V DC maximum
- Rated Current: 50 mA per output
- Response Time: ≤ 200 µs fast switching
- 1-Signal Level: (External voltage) - 3V max at 50 mA
- 0-Signal Level: Blocked output (≤10 µA leakage)
- Switching Frequency: ≤ 5 kHz maximum
Safety & Isolation
- Safety Level: SIL 2, Systematic Capability SC 3
- Galvanic Isolation: Reinforced insulation 300 Veff
- Isolation Ratings: Input/Output: 300 Veff reinforced
- Hazardous Area: ATEX certified [Ex ia Ga] IIC
- Protection Degree: IP20 for indoor use
Configuration & Display
- Configuration: DIP switch settings
- Display Elements: LED status indicators
- Labeling: Front space for identification
- Operating Mode: Reversible operation possible
- Signal Splitting: 1 input to 2 outputs capability
Environmental Specifications
- Temperature Range: -20°C to +70°C standard
- Extended Range: Up to 70°C with derating
- Mounting: 35 mm DIN rail per EN 60715
- Dimensions: 12.5 x 119 x 114 mm (WxHxD)
- Weight: Approx. 100 grams
Certifications & Compliance
- ATEX Certificate: BASEEFA 13 ATEX 0080
- Marking: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC
- EMC Directive: 2014/30/EU, EN 61326-1:2013
- Safety Standards: IEC 61010-1:2010 compliance
Installation Guidelines
- Mount on 35 mm DIN rail in appropriate enclosure
- Connect 24V DC power via Power Rail or terminals
- Wire NAMUR sensor or dry contact to input terminals
- Connect outputs to control system inputs
- Configure DIP switches for required operation mode
- Verify proper grounding for hazardous area installation
Frequently Asked Questions (FAQ)
What is the main purpose of this switch amplifier?
The Pepperl+Fuchs KCD2-SOT-Ex1.LB safely interfaces hazardous area sensors with control systems.
Can I use this with standard mechanical contacts?
Yes, it accepts both NAMUR sensors and dry contact inputs.
What does "signal splitter" function mean?
It can take one input signal and provide two identical output signals.
How does line fault detection work?
It detects open circuits (<0.1 mA) and short circuits (>6.5 mA) in field wiring.
What hazardous area classifications does it support?
ATEX Zone 0/1 for gas and Zone 20/21 for dust explosive atmospheres.
What configuration options are available?
DIP switches allow setting operating mode, output configuration, and fault behavior.
For technical specifications or to order the KCD2-SOT-Ex1.LB, email sale@etowonauto.com.
Content provided by Etowon Auto.
Ytterligere spesifikasjoner
- Blå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvordan optimaliserer full livssyklusforvaltning PLC- og DCS-ressurser?
Tradisjonell industriell eiendelsforvaltning er avhengig av manuell logging og reaktiv feilsøking, noe som fører til ...
-
Kan en integrert reservedelkjede redusere nedetiden?
Uplanlagte utstyrsfeil koster kinesiske fabrikker ¥636 000 per time. Tradisjonell grenseoverskridende reservedelsinnk...
-
Hvorfor mislykkes 30 % av automatiseringsoppgraderinger på grunn av integrasjonsmangler?
Denne tekniske artikkelen forklarer hvordan digital-intelligent fusjon overkommer fragmenterte verkstedsoperasjoner v...
-
Hvorfor stoler tunge industrier på GE Fanuc PLC- og DCS-systemer?
Denne artikkelen undersøker hvordan GE Fanuc-kjernekomponenter løser pålitelighetsproblemer i tungbelastet fabrikkaut...
-
Hvordan forutsier Bently Nevada feil 180 dager i forveien?
Standard PLC- og DCS-systemer overser ofte tidlige vibrasjonsavvik i roterende maskineri, noe som fører til 68 % av p...
-
Hvordan eliminerer ABB Omni-Measurement blinde soner i prosessikkerhet?
ABB Omni-Measurement lukker blinde soner i prosessikkerhet ved hjelp av prediktiv analyse og kryssvalidert sensortekn...
