Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:V18345-1010251001
Intelligent Positioner IP65 | ABB TZIDC-120 V18345-1010251001
Manufacturer: ABB
Product No.: V18345-1010251001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
ABB V18345-1010251001 TZIDC-120 Intelligent Positioner
Product Overview
ABB V18345-1010251001 is a TZIDC-120 intelligent positioner with configurable indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail freeze action. Cable connection M20x1.5 and air pipe 1/4-18 NPT. Includes plug-in analog position feedback module 4-20mA.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC-120 Intelligent Positioner |
| Case/Mounting | 2 | Varnished aluminum IP65, DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter connector |
| Explosion Protection | 0 | Without |
| Output/Safe Position | 2 | Single acting, fail freeze |
| Connections | 5 | Cable M20x1.5, Air 1/4-18 NPT |
| Option Modules | 1 | Plug-in analog position feedback 4-20mA |
| Mech Feedback | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010251001 |
| Type | TZIDC-120 Intelligent Positioner |
| Action | Single Acting, Fail Freeze |
| Signal Range | 4 to 20 mA two-wire |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h (0.015 scfm) |
| Action Signal | Direct 4-20mA = 0-100%, Reverse 20-4mA = 0-100% |
| Characteristic Curve | Linear, equal percentage 1:25/1:50/25:1/50:1, 20 points |
| Characteristic Deviation | ≤ 0.5% |
| Tolerance Band | 0.3 to 10% adjustable |
| Dead Band | 0.1 to 10% adjustable |
| Resolution A/D | > 4000 steps |
| Sample Rate | 20 ms |
| Temp Influence | ≤ 0.5% per 10°C |
| Vibration Influence | ≤ ±1% up to 10g and 80Hz |
| Seismic | DIN/IEC 68-3-3 Class III |
| Mounting Orientation | No effect |
| Electrical Connection | M20x1.5 |
| Pneumatic Connection | 1/4-18 NPT |
| Protection Class | IP65, NEMA 4X |
| Weight | 1.7 kg (3.75 lbs) |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at M20x1.5. Connect air supply at 1/4-18 NPT with 1.4 to 6 bar pressure. Do not exceed maximum operating pressure of the actuator. Configure characteristic curve via 20 reference points. Verify IP65 seal after installation.
Features
TZIDC-120 intelligent positioner with configurable indicator and operator panel. Single acting fail freeze action. 4-20mA two-wire input with LKS adapter. Plug-in analog position feedback 4-20mA. Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Air consumption less than 0.03 kg/h independent of supply pressure. Seismic rated per DIN/IEC 68-3-3 Class III. No effect from mounting orientation. Aluminum case with epoxy resin varnish IP65 NEMA 4X. Weight 1.7 kg.
FAQ
Q1: What is the action type and fail position?
A1: Single acting with fail freeze action. In case of electrical failure, the actuator is blocked or air is vented depending on configuration.
Q2: What is the air consumption and supply pressure?
A2: Air consumption less than 0.03 kg/h independent of supply pressure. Supply pressure range 1.4 to 6 bar (20 to 90 psi).
Q3: What is the characteristic deviation and resolution?
A3: Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Tolerance band adjustable 0.3 to 10%. Weight 1.7 kg.
Ytterligere spesifikasjoner
- Sølv
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...