Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:IC200CBL120
GE VersaMax IC200CBL120 Unshielded Expansion Cable 2 Meters
Manufacturer: General Electric
Product No.: IC200CBL120
Product Type: Expansion Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The IC200CBL120 is a dedicated 2-meter I/O expansion cable manufactured by GE Fanuc (now Emerson) for the VersaMax PLC series. Weighing 2.00 lbs (0.91 kg), this unshielded assembly features 2 high-density connectors designed to bridge communication across VersaMax I/O carriers. Engineered to operate reliably between 0 and 60 °C, it enables high-speed signal routing and system expansion across connector-style carrier bases.
Core Technical Advantages
- VersaMax Carrier Compatibility: Seamlessly interfaces with IC200CH003, IC200CH011, IC200CH012, and IC200CH015 modules.
- Dual-Connector Design: Equipped with 2 precision-molded connectors for fast, reliable plug-and-play installation between carriers.
- Industrial Heat Tolerance: Rated for full continuous operation in enclosure temperatures from 0 °C to 60 °C.
- Heavy-Duty Mechanical Build: Robust 0.91 kg (2.00 lbs) construction ensures cable longevity in high-vibration control cabinets.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | GE Fanuc / Emerson Automation |
| Part Number | IC200CBL120 |
| Product Series | VersaMax PLC I/O System |
| Product Type & Function | Unshielded I/O Expansion Cable |
| Cable Length | 2 Meters (approx. 6.5 feet) |
| Net Weight | 2.00 lbs (0.91 kg) |
| Connector Count & Type | 2 Connectors (Connector-Style Carrier Support) |
| Operating Temperature | 0 °C to 60 °C (32 °F to 140 °F) |
| Module Compatibility | IC200CH003, IC200CH011, IC200CH012, IC200CH015 |
Industrial Solutions
- Multi-Rack PLC Expansion: Connects adjacent VersaMax carrier bases across separate enclosure DIN rails.
- Factory Automation Control: Links I/O modules to main processors in automated assembly lines.
- Remote I/O Cabinets: Provides reliable signal continuity between distributed carrier racks in industrial plants.
Wiring & Installation
System Power Preparation
Shut down power to the VersaMax PLC rack before connecting expansion components to avoid hardware damage.
Carrier Socket Alignment
Align the 2 connectors on the 2-meter cable with the expansion ports on the IC200CH series connector-style carriers.
Cable Routing & Support
Route the 2.00 lbs (0.91 kg) cable neatly inside wiring ducts, avoiding sharp bends and high-voltage AC power lines.
Connector Engagement
Press connectors firmly into carrier sockets until latched to establish full pin contact and electrical continuity.
Engineering Advantages
- Optimized Length: 2-meter span allows flexible placement of I/O expansion racks within control cabinets.
- Precise Electrical Fit: Matches internal impedance specifications for seamless VersaMax backplane communication.
- Direct OEM Compatibility: Replaces worn expansion cables with 100% functional match for GE/Emerson systems.
Technical FAQs
Q1: Which VersaMax carriers work with IC200CBL120?
A1: Compatible with IC200CH003, IC200CH011, IC200CH012, and IC200CH015 connector-style carriers.
Q2: What are the physical specs of this expansion cable?
A2: Unshielded cable, 2 meters long, weighing 2.00 lbs (0.91 kg) with 2 connectors.
Q3: What temperature range can IC200CBL120 tolerate?
A3: Operates continuously in standard industrial temperatures ranging from 0 °C to 60 °C.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does S7-400H Redundant PLC Work in DCS Projects?
Siemens SIMATIC S7-400 PLC remains a proven platform for large-scale industrial automation, combining redundant ...
-
How Does ABB AC500 PLC Support DCS Integration?
The ABB AC500 modular PLC delivers scalable hardware, fast CPU cycles, and native DCS communication for modern indust...
-
Can Legacy GE 90-70 PLCs Integrate with Modern DCS Systems?
GE Series 90-70 PLC modules remain critical for aging industrial control systems, and redundant hardware configu...
-
What Makes the Bently Nevada 177230 Ideal for Casing Monitoring?
The Bently Nevada 177230 seismic transmitter delivers reliable casing vibration monitoring for auxiliary rotating mac...
-
Can PLC and DCS Replace Dedicated TSI Protection?
This article examines why critical rotating machinery requires independent safety barriers separate from standard PLC...
-
Can Bently Nevada TSI Prevent Turbine Trips in Automation?
This technical article examines why standard PLC and DCS process monitoring fails to detect early-stage rotating mach...