Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:IC698PSA100E
GE Fanuc IC698PSA100E | RX7i 120/240V AC Power Supply
Manufacturer: General Electric
Product No.: IC698PSA100E
Product Type: Power Supply Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 800g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
GE Fanuc IC698PSA100E PACSystems RX7i Power Supply Module
Product Overview
The IC698PSA100E is a high-capacity power supply module engineered specifically for the GE Fanuc PACSystems RX7i controller series. Occupying the dedicated Slot 0 (the leftmost slot) of the RX7i rack, this module provides the essential regulated DC power required for the CPU and all associated I/O modules. It is designed for maximum versatility, accepting both AC and DC input voltages to suit various global industrial standards. With a robust 20A output capacity, it ensures stable system performance even in fully populated rack configurations across demanding automation environments.
Core Technical Advantages
This power module is built for efficiency and thermal stability, boasting an 85% energy conversion efficiency that minimizes heat generation within the control cabinet. It features a wide input voltage range, supporting 85 to 264 VAC or 100 to 150 VDC, making it resilient to fluctuations in industrial power grids. The module delivers multiple regulated output voltages, including +5 VDC, +12 VDC, and -12 VDC, providing comprehensive power support for the backplane logic and communication circuits. Designed for extreme reliability, it maintains peak performance across an extended operating temperature range of -25°C to +60°C.
Technical Specifications
| Feature | Specification |
|---|---|
| Brand | GE Fanuc (PACSystems RX7i) |
| Catalog Number | IC698PSA100E |
| Input Voltage | 120/240 VAC or 125 VDC |
| Output Current | 20 Amps (Total) |
| Product Weight | 0.8 kg (1.76 lbs) |
| Efficiency | 85% Typical |
| Mounting | Slot 0 (RX7i Rack) |
Installation & Engineering Guide
Installation of the power supply must be performed in Slot 0 of the PACSystems RX7i rack. Before applying power, ensure the input voltage matches the nominal ratings of 120/240 VAC or 125 VDC to prevent hardware damage. The module features 125W of input power capacity, which is sufficient to drive high-performance CPU modules and a wide range of discrete and analog I/O. Proper ventilation should be maintained around the rack to leverage the module's high operating temperature threshold. It is also recommended to use dedicated grounding to minimize electrical noise interference with the backplane communication signals.
Engineering Advantages
The PACSystems RX7i architecture is known for its high-speed VME-based backplane. This power module is essential for maintaining that high-performance standard, providing clean and consistent DC outputs to the rack. Despite its heavy-duty current delivery, the module features a optimized design with a shipping weight of approximately 0.8 kg, ensuring it does not add unnecessary mechanical stress to the rack assembly. By consolidating high-efficiency power delivery and versatile input options into a single slot, the module simplifies system design and reduces the footprint required for large-scale industrial controllers in power generation and heavy manufacturing.
Technical FAQs
Q1: Can this power supply be installed in any slot?
A1: No, this module is specifically keyed and designed for Slot 0 (the leftmost position) in the RX7i rack. It cannot be placed in standard I/O slots.
Q2: Does it support both AC and DC inputs simultaneously?
A2: While the module is compatible with both 120/240 VAC and 125 VDC power sources, only one type of input should be connected and used as the primary power source at any given time.
Q3: Is a Certificate of Origin (COO) available for this module?
A3: Yes, we provide official documentation, including a Certificate of Origin, for all our GE Fanuc components to support international trade and compliance requirements.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvordan optimaliserer full livssyklusforvaltning PLC- og DCS-ressurser?
Tradisjonell industriell eiendelsforvaltning er avhengig av manuell logging og reaktiv feilsøking, noe som fører til ...
-
Kan en integrert reservedelkjede redusere nedetiden?
Uplanlagte utstyrsfeil koster kinesiske fabrikker ¥636 000 per time. Tradisjonell grenseoverskridende reservedelsinnk...
-
Hvorfor mislykkes 30 % av automatiseringsoppgraderinger på grunn av integrasjonsmangler?
Denne tekniske artikkelen forklarer hvordan digital-intelligent fusjon overkommer fragmenterte verkstedsoperasjoner v...
-
Hvorfor stoler tunge industrier på GE Fanuc PLC- og DCS-systemer?
Denne artikkelen undersøker hvordan GE Fanuc-kjernekomponenter løser pålitelighetsproblemer i tungbelastet fabrikkaut...
-
Hvordan forutsier Bently Nevada feil 180 dager i forveien?
Standard PLC- og DCS-systemer overser ofte tidlige vibrasjonsavvik i roterende maskineri, noe som fører til 68 % av p...
-
Hvordan eliminerer ABB Omni-Measurement blinde soner i prosessikkerhet?
ABB Omni-Measurement lukker blinde soner i prosessikkerhet ved hjelp av prediktiv analyse og kryssvalidert sensortekn...
