Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:IC697MDL940
GE Fanuc IC697MDL940 Series 90-70 16-Channel Relay Output Module
Manufacturer: General Electric
Product No.: IC697MDL940
Product Type: Relay Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The GE Fanuc IC697MDL940 is a versatile 16-channel relay output module engineered for the Series 90-70 Programmable Logic Controller system. This module provides a flexible interface between the PLC backplane and external field devices, utilizing a combination of eight Form C (Normally Open/Normally Closed) and eight Form A (Normally Open) contacts. Designed for high reliability in complex switching applications, the IC697MDL940 supports a wide range of voltages, making it an essential component for controlling motors, valves, and indicators in diverse industrial settings.
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | IC697MDL940 (Series 90-70) |
| Output Channels | 16 Total (8 Form C, 8 Form A) |
| Rated Voltage (AC) | 120/240 VAC (Range: 5-265 VAC) |
| Rated Voltage (DC) | 5/24/125 VDC (Range: 5-30 VDC) |
| Maximum Load | 2.0 Amps per contact |
| Module Weight | Approximately 150 g (0.33 lbs) |
| Backplane Isolation | 1500 Volts |
| Power Dissipation | 5.5 Watts |
Core Technical Advantages
Mixed Contact Configuration
The IC697MDL940 distinguishes itself by offering both Form A and Form C relay types within a single module slot. This hybrid design allows engineers to handle both basic switching and changeover logic simultaneously, reducing the total number of modules required in the PLC rack.
Superior Inrush Handling
Built to survive the demands of inductive loads, the module features silver-alloy contacts capable of managing an inrush current of up to 15A for 50ms. This ensures long-term contact durability when driving solenoids or small motor starters that exhibit high initial current spikes.
High-Voltage Isolation Protection
To protect the sensitive Series 90-70 CPU and backplane, the IC697MDL940 provides 1500V isolation. This barrier prevents field-side electrical surges from migrating to the control logic, significantly increasing overall system uptime and safety.
Installation & Maintenance
- Mechanical Keying: Utilize the module's unique keying feature to prevent accidental insertion into the wrong rack slot during field maintenance.
- Fuse Protection: Each channel is protected by a 3A fuse. Always verify field load requirements do not exceed the 2.0A continuous rating to prevent nuisance blowing.
- Contact Lifespan: For high-frequency switching (exceeding 20 cycles per minute), consider external snubbers for inductive loads to extend the silver-alloy contact life beyond the standard 90,000-hour MTBF.
Engineering Advantages
The IC697MDL940 is optimized for rugged environments, maintaining full functionality across an operating temperature range of –25°C to 70°C. Despite its lightweight design of only 150 g, the module is built for industrial resilience. Its low internal power dissipation (5.5W) minimizes heat buildup within the PLC enclosure, while the 10mA minimum load capability ensures compatibility with modern electronic relay coils.
Technical FAQs
Q1: Can I mix AC and DC voltages on the same IC697MDL940 module?
A1: Yes. Relays are dry contacts, meaning you can switch different voltages on different channels, provided you observe group load limits and ensure proper wiring isolation between circuits.
Q2: What is the difference between Form A and Form C contacts on this module?
A2: The module provides 8 Form A contacts (Normally Open) and 8 Form C contacts (Single Pole Double Throw). Form C contacts provide both a Normally Open and a Normally Closed terminal for every common wire.
Q3: Is this module hot-swappable?
A3: Standard Series 90-70 procedures require the system power to be off when removing or inserting modules to prevent backplane arcing and ensure data integrity.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...
-
Standardised 3300 Probe Workflow Cuts False Trips by 90%?
Uncalibrated Bently Nevada 3300 probe replacements are responsible for 68% of false turbine trips, costing power plan...
-
Mixed GE Fanuc & ABB Servo Faults? Fix Heavy Lathe Downtime Now?
This guide presents a data-driven Standard Operating Procedure for diagnosing cross-brand motion control faults in he...
