Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:VFD485VP43AFTHA
Delta VFD485VP43AFTHA | 3-Phase 460V 91A Drive
Manufacturer: Delta
Product No.: VFD485VP43AFTHA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Delta VFD485VP43AFTHA is a high-capacity Variable Frequency Drive (VFD) engineered for heavy-duty industrial fluid control. With a robust output of 45kW (60HP), this drive excels in managing large-scale HVAC systems, water treatment pumps, and industrial cooling towers. This specific "THA" variant incorporates enhanced thermal management and an integrated DC reactor to suppress harmonic distortion, ensuring compliance with strict power quality standards. Its advanced Sensorless Vector Control (SVC) provides the perfect balance between high starting torque and energy-efficient cruise speeds.
Technical Configuration
Model Specification Logic
- Power Rating (485): Delivers a rated output current of 91 Amps, supporting motors up to 45kW (60HP).
- Series (VP): Specialized for variable torque loads, offering a multi-pump control mode and fire mode for emergency fan operation.
- Voltage Class (43): 460V 3-Phase input (compatible with 380V–480V ±10% utility grids).
- Filter & Reactor (AF): Includes a built-in EMC filter (Class A) and an internal DC reactor to reduce THDi (Total Harmonic Distortion).
- Frame Configuration (THA): Features a reinforced chassis with an independent cooling duct design to isolate power components from dust.
Technical Specifications
| Parameter | Data Value Details |
|---|---|
| Rated Output Current | 91 A (Normal Duty) |
| Applicable Motor Output | 45 kW / 60 HP |
| Input Current | 86 A (3-Phase AC) |
| Braking Torque | Approx. 20% (Standard); up to 125% with external unit |
| Starting Torque | 150% at 0.5Hz (SVC mode) |
| Frequency Stability | Digital: ±0.01%; Analog: ±0.2% |
| Efficiency | ≥ 97.5% at rated load |
| Enclosure Rating | IP20 (Standard) / NEMA 1 Optional |
Installation & Maintenance Guide
High-Power Engineering Standards
Power Quality: The integrated DC reactor in the VFD485VP43AFTHA significantly reduces harmonics. No additional line reactor is required unless the power source impedance is less than 3%. This reduces both installation footprint and overall system cost.
Cooling Architecture: This model utilizes an isolated cooling duct. When mounting in a cabinet, ensure the exhaust air is vented directly out of the enclosure to prevent internal heat buildup. The drive’s fans are field-replaceable to ensure long-term uptime.
Torque Terminal Torque: For the 91A output terminals, use M6 or M8 ring terminals with a tightening torque of 4.0-5.0 N-m to prevent hot spots caused by loose electrical connections.
Engineering Advantages
The VFD485VP43AFTHA features an Advanced Multi-Pump Control logic, capable of managing up to 4 pumps simultaneously (1 master fixed speed + 3 auxiliary). It includes a built-in RS-485 interface supporting Modbus RTU/ASCII with speeds up to 38.4kbps. Its 4-layer conformal coating protects the 45kW power bridge and control logic from moisture and chemical vapors, making it suitable for wastewater treatment facilities and chemical processing plants.
Technical FAQs
Q1: What is the maximum carrier frequency for this 45kW model?
A1: The carrier frequency can be set between 2kHz and 10kHz. For a 45kW drive, 4kHz is the recommended default to balance switching losses and acoustic motor noise.
Q2: Can I run this drive on a single-phase supply for testing?
A2: No. High-power VP series drives require a balanced 3-phase input to prevent phase-loss protection trips and potential damage to the input rectifier bridge.
Q3: How does the "Fire Mode" work in this drive?
A3: When activated via a digital input, the VFD ignores non-critical alarms and runs at a preset frequency to ensure smoke extraction or water pressure is maintained during emergency events.
Ytterligere spesifikasjoner
- Svart
- Grå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvordan optimaliserer full livssyklusforvaltning PLC- og DCS-ressurser?
Tradisjonell industriell eiendelsforvaltning er avhengig av manuell logging og reaktiv feilsøking, noe som fører til ...
-
Kan en integrert reservedelkjede redusere nedetiden?
Uplanlagte utstyrsfeil koster kinesiske fabrikker ¥636 000 per time. Tradisjonell grenseoverskridende reservedelsinnk...
-
Hvorfor mislykkes 30 % av automatiseringsoppgraderinger på grunn av integrasjonsmangler?
Denne tekniske artikkelen forklarer hvordan digital-intelligent fusjon overkommer fragmenterte verkstedsoperasjoner v...
-
Hvorfor stoler tunge industrier på GE Fanuc PLC- og DCS-systemer?
Denne artikkelen undersøker hvordan GE Fanuc-kjernekomponenter løser pålitelighetsproblemer i tungbelastet fabrikkaut...
-
Hvordan forutsier Bently Nevada feil 180 dager i forveien?
Standard PLC- og DCS-systemer overser ofte tidlige vibrasjonsavvik i roterende maskineri, noe som fører til 68 % av p...
-
Hvordan eliminerer ABB Omni-Measurement blinde soner i prosessikkerhet?
ABB Omni-Measurement lukker blinde soner i prosessikkerhet ved hjelp av prediktiv analyse og kryssvalidert sensortekn...
