Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:3500/25-01-03-02
Bently Nevada 3500/25-01-03-02 Enhanced Keyphasor Module
Manufacturer: Bently Nevada
Product No.: 3500/25-01-03-02
Product Type: Enhanced Keyphasor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 3500/25-01-03-02 Enhanced Keyphasor Module
The 3500/25-01-03-02 Enhanced Keyphasor Module provides precise reference signals for speed and phase measurement in turbomachinery. It delivers reliable Keyphasor pulses to the monitoring system, enabling accurate synchronous sampling and diagnostics for gas turbines, steam turbines, and compressors. This module is ATEX/IECEx certified for hazardous area installations.
Ordering Code Configuration
The 3500/25-01-03-02 part number follows this structure: 3500/25-AA-BB-CC
- AA – Channel Configuration: 01 = Single half-height 2-channel Keyphasor card (option for 2 channels)
- BB – I/O Module Type: 03 = Internal Barrier I/O with Internal Terminations
- CC – Agency Approval: 02 = ATEX/IECEx/CSA (Class 1 Zone 2)
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bently Nevada |
| Product Number | 3500/25-01-03-02 |
| Channel Configuration | Single half-height 2-channel Keyphasor card |
| I/O Module Type | Internal Barrier I/O with Internal Terminations |
| Agency Approval | ATEX/IECEx/CSA (Class 1 Zone 2) |
| Main Module Dimensions | 119.9 x 24.4 x 256.5 mm (4.72 x 0.96 x 10.10 in) |
| Main Module Weight | 0.34 kg (0.76 lbs) |
| I/O Module Dimensions | 241.3 x 24.4 x 103.1 mm (9.50 x 0.96 x 4.06 in) |
| I/O Module Weight | 0.46 kg (1.01 lbs) |
| Operating Temperature (Standard I/O) | -30°C to +65°C (-22°F to +150°F) |
| Operating Temperature (Internal Barrier I/O) | 0°C to +65°C (32°F to +150°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity (non-condensing) | 95% |
Installation & Field Application Guide
- Install the Keyphasor module in any half-height front slot of the 3500 rack. The I/O module occupies the corresponding rear slot.
- For Internal Barrier I/O, observe the reduced operating temperature range of 0°C to +65°C. Ensure adequate cabinet cooling.
- Use shielded twisted-pair cables for Keyphasor signal wiring. Maintain a minimum bend radius of 10x cable diameter.
- In hazardous area installations (ATEX/IECEx), ensure proper cable glands and sealing per local certification requirements.
Why Choose the 3500/25-01-03-02
- Provides precise Keyphasor pulses for accurate speed and phase measurement.
- Internal Barrier I/O eliminates the need for external safety barriers in hazardous areas.
- ATEX/IECEx/CSA certification allows installation in Class 1 Zone 2 environments.
- Compact half-height design saves rack space while delivering 2-channel capability.
Field Engineer FAQs
Q1: What is the difference between standard I/O and Internal Barrier I/O?
A1: Internal Barrier I/O includes built-in galvanic isolation and zener barriers for hazardous area installations. This eliminates the need for external safety barriers but reduces the operating temperature range to 0°C to +65°C.
Q2: How many Keyphasor channels does this module provide?
A2: The 3500/25-01-03-02 provides 2 Keyphasor channels on a single half-height card. Each channel accepts a proximity probe or magnetic pickup input.
Q3: What is the recommended sensor type for Keyphasor input?
A3: Bently Nevada recommends 3300 XL 8mm proximity probes or magnetic pickups with a voltage output between -0.8V and -21V DC. Ensure the sensor is properly gapped per the installation manual.
Inquiries: sale@etowonauto.com
Ytterligere spesifikasjoner
- Blå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
