Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:3500/25-01-01-02
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module
Manufacturer: Bently Nevada
Product No.: 3500/25-01-01-02
Product Type: Enhanced Keyphasor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 460g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module for 3500 Machinery Protection System. Half-height, two-channel module converts proximity probe or magnetic pickup signals into digital Keyphasor outputs. ATEX/IECEx/CSA certified for Class 1 Zone 2 hazardous areas. Provides precise timing for shaft speed, phase, and vector measurements.
Key Features
2-channel half-height module. Input range 1 to 1,200,000 cpm (0.017 to 20 kHz). Output range 1 to 99,999 cpm. Auto or manual threshold triggering. Buffered Keyphasor outputs at front and rear. -24 Vdc transducer power supply. 3.2W typical power consumption. ATEX/IECEx/CSA Class 1 Zone 2 approval. Supports up to four Keyphasor signals standard, eight in paired configuration. Direct replacement for 125792-01.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 3500/25-01-01-02 |
| Product Type | Enhanced Keyphasor Module |
| Channels (Option A) | 01 = Single 2-channel card |
| I/O Module Type (Option B) | 01 = Internal Terminations |
| Agency Approval (Option C) | 02 = ATEX/IECEx/CSA (Class 1 Zone 2) |
| Input Frequency Range | 1 to 1,200,000 cpm (0.017 to 20 kHz) |
| Output Frequency Range | 1 to 99,999 cpm (0.017 to 1667 Hz) |
| Accuracy (Non-processed) | ±1 cpm (0.017-100Hz), ±8 cpm (101-500Hz), ±1% (501-20kHz) |
| Input Impedance | 21.8 kΩ minimum |
| Auto Threshold | 2V p-p min, 120 rpm (2Hz) min |
| Manual Threshold | 0 to -20Vdc, 500mV p-p min |
| Hysteresis | User-selectable 0.2 to 2.5V |
| Transducer Power Supply | -24 Vdc, 40 mA max per channel |
| Power Consumption | 3.2 W typical |
| Main Module Dimensions | 119.9 x 24.4 x 256.5 mm (4.72 x 0.96 x 10.10 in) |
| Main Module Weight | 0.34 kg (0.76 lbs) |
| I/O Module Dimensions | 241.3 x 24.4 x 103.1 mm (9.50 x 0.96 x 4.06 in) |
| I/O Module Weight | 0.46 kg (1.01 lbs) |
| Rack Space (Main) | 1 half-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Operating Temperature | -30°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 95%, non-condensing |
| Origin | Made in U.S.A. |
Ordering Code Breakdown
3500/25-01-01-02
A:01 – Single half-height 2-channel Keyphasor card.
B:01 – I/O module with Internal Terminations.
C:02 – ATEX/IECEx/CSA (Class 1 Zone 2) approval.
Installation Notes
Install in half-height front slot using mounting adapter. I/O module occupies corresponding full-height rear slot. For hazardous area installation, follow control drawing 149243 or 149244. Configure trigger threshold (auto or manual) and hysteresis per application. Use Internal Terminations (B:01) for standard proximity probe applications.
Engineering Advantages
ATEX/IECEx/CSA Class 1 Zone 2 certification enables installation in hazardous areas. Supports up to eight Keyphasor signals in paired configuration. Expanded frequency range handles multi-event-per-turn inputs up to 20 kHz. Direct replacement for legacy 125792-01 modules. Buffered outputs at front and rear simplify external diagnostics. Field-upgradeable firmware protects investment.
FAQs
Q1: What is the maximum input frequency?
A1: 20 kHz (1,200,000 cpm), supporting multiple events per revolution.
Q2: What approvals does the 02 option provide?
A2: ATEX/IECEx/CSA certification for Class 1 Zone 2 hazardous areas.
Q3: Can this module replace older Keyphasor modules?
A3: Yes, the Enhanced Keyphasor Module is a direct plug-in replacement for Keyphasor Module 125792-01.
Ytterligere spesifikasjoner
- Blå
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...