Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:330905-00-13-05-12-00
Bently Nevada 330905-00-13-05-12-00 | Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330905-00-13-05-12-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Bently Nevada 330905-00-13-05-12-00 is a 3300 NSv proximity probe with an M10×1 thread, 130 mm case length, and 0.5 m miniature coaxial ClickLoc cable with FluidLoc construction. It measures shaft vibration and axial position on turbines, compressors, and pumps with a 1.5 mm linear range and 7.87 V/mm scale factor. Each probe weighs approximately 0.45 kg, keeping bracket loading low. The FluidLoc cable resists moisture ingress in wet process compressor service, while the PPS tip and AISI 304 stainless steel case handle chemical exposure.
Technical Configuration
Model Code Breakdown
The 330905 code defines the NSv probe family. The -00- option sets a 0 mm unthreaded length. The -13- option sets a 130 mm overall case length. The 05 option sets a 0.5 m total length. The 12 option specifies a miniature coaxial ClickLoc connector with FluidLoc cable. The -00 agency approval option means no certification required.
Core Hardware
The probe uses a polyphenylene sulfide tip and AISI 304 stainless steel case. The 75 Ω coaxial FEP cable with FluidLoc construction carries the signal to the ClickLoc connector. A Viton O-ring seals differential pressure between the probe tip and case. The probe is mechanically and electrically interchangeable with the earlier 3300 RAM probe and extension cable.
Technical Specifications
| Parameter | Specification |
| Linear Range | 1.5 mm (60 mils), 0.25 to 1.75 mm |
| Recommended Gap | 1.0 mm (40 mils) |
| Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz, +0/-3 dB typical |
| Probe DC Resistance | 4.0 ± 0.5 ohms at 0.5 m |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Target Size | Min 8.9 mm, recommended 13 mm |
| Thread | M10×1, 15 mm max engagement |
| Probe Case Torque | 7.5 N·m recommended, 22.6 N·m max |
| Field Wiring | 0.2 to 1.5 mm², max 305 m |
| Weight | Approx. 0.45 kg |
Installation Guide
Set the gap at 1.0 mm (40 mils) using a feeler gauge or the -1 to -13 Vdc output reading. Keep the minimum bend radius at 25.4 mm to avoid cable damage. Apply 7.5 N·m torque to the M10×1 probe case, never exceeding 22.6 N·m. Use three-conductor shielded triad cable for field wiring and keep total length under 305 meters. At roughly 0.45 kg, the probe adds minimal load to the mounting bracket. Confirm the Viton O-ring seats correctly before pressurizing the machine.
Engineering Advantages
The NSv probe delivers higher chemical resistance than the 3300 RAM probe, extending service life in process compressor environments. The FluidLoc cable blocks moisture wicking along the cable core, a common failure point in washdown and humid areas. Its side-view characteristics outperform the 3000-series 190 probe when gapping at the same distance from the target. The probe and extension cable interchange directly with existing 3300 RAM installations, cutting upgrade downtime. The lightweight 0.45 kg body reduces bracket stress.
Technical FAQs
Q1: What is the difference between standard cable and FluidLoc cable?
A1: FluidLoc construction seals the cable core against fluid migration. Choose it for wet, humid, or washdown locations where standard cable may allow moisture to travel toward the connector.
Q2: How do I set the probe gap?
A2: Target 1.0 mm (40 mils), which corresponds to roughly -10 Vdc. Confirm the reading falls within the -1 to -13 Vdc linear range before locking the probe.
Q3: Is this probe interchangeable with the older 3300 RAM probe?
A3: Yes. The 3300 NSv probe and extension cable are mechanically and electrically compatible with the previous 3300 RAM probe and extension cable.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...