Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:330101-00-34-10-02-05
Bently Nevada 330101-00-34-10-02-05 8mm Probe
Manufacturer: Bently Nevada
Product No.: 330101-00-34-10-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 330101-00-34-10-02-05 3300 XL 8mm Probe
The Bently Nevada 330101-00-34-10-02-05 is a 3300 XL 8 mm proximity probe with 3/8-24 UNF thread, without armor. This probe delivers precise non-contact vibration and position measurements for turbomachinery. Featuring patented TipLoc and CableLoc designs, it provides 330 N (75 lbf) pull strength. Weighing 323 g/m (11.4 oz/ft), it operates from -52°C to +177°C with a linear range of 2 mm (80 mils).
Ordering Code Configuration
The 330101-00-34-10-02-05 part number follows this structure:
- 330101 – 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor
- 00 – Unthreaded Length: 0.0 in
- 34 – Overall Case Length: 3.4 in
- 10 – Total Length: 1.0 meter (3.3 feet)
- 02 – Connector: Miniature coaxial ClickLoc, standard cable
- 05 – Agency Approval: CSA, ATEX, IECEx
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bently Nevada |
| Model Number | 330101-00-34-10-02-05 |
| Probe Type | 3300 XL 8 mm, without armor |
| Thread | 3/8-24 UNF |
| Overall Case Length | 3.4 in (86.4 mm) |
| Total Length | 1.0 m (3.3 ft) |
| Connector | Miniature coaxial ClickLoc |
| Agency Approval | CSA, ATEX, IECEx |
| Weight | 323 g/m (11.4 oz/ft) |
| Probe DC Resistance (1.0m) | 7.59 ± 0.50 Ω |
| Linear Range | 2 mm (80 mils) from 0.25 to 2.3 mm |
| Incremental Scale Factor | 7.87 V/mm (200 mV/mil) ±5% |
| Recommended Gap (Radial) | -9 VDC [~1.27 mm (50 mils)] |
| DSL (1.0m System) | Less than ±0.025 mm (±1 mil) |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303/304 Stainless Steel |
| Operating Temperature | -52°C to +177°C (-62°F to +350°F) |
| Storage Temperature | -52°C to +177°C (-62°F to +350°F) |
| Probe Pressure Seal | Viton® O-ring |
Field Wiring Specifications
| Parameter | Value |
|---|---|
| Wire Size | 0.2 to 1.5 mm² (16 to 24 AWG) |
| Cable Type | 3-conductor shielded triad |
| Max Field Wiring Length | 305 m (1000 ft) |
| Extension Cable Capacitance | 69.9 pF/m (21.3 pF/ft) typical |
Installation & Field Application Guide
- Install the probe with the recommended gap of -9 VDC [approximately 1.27 mm (50 mils)] for radial vibration measurement.
- Use 3-conductor shielded triad cable for field wiring. Maximum length is 305 m (1000 ft) between the Proximitor and monitor.
- For FluidLoc option applications, ensure the cable seal prevents oil or liquid leakage through the cable interior.
- For hazardous area installations, verify the probe is used with an appropriate intrinsically safe barrier per the agency approval (CSA, ATEX, IECEx).
Why Choose the 3300 XL 8mm Probe
- Thicker encapsulation of the probe coil in molded PPS plastic for a more rugged probe.
- Patented TipLoc molding provides robust bond between probe tip and body.
- Patented CableLoc design delivers 330 N (75 lbf) pull strength.
- Larger diameter probe body offers stronger, more robust case construction.
Field Engineer FAQs
Q1: What is the recommended gap voltage for this probe?
A1: The recommended gap setting for radial vibration is -9 VDC, which corresponds to approximately 1.27 mm (50 mils).
Q2: What approvals does the 05 option provide?
A2: The 05 agency approval option includes CSA (Class 1 Division 2), ATEX, and IECEx certifications for hazardous area installations.
Q3: What is the maximum field wiring length between probe and monitor?
A3: Maximum field wiring length is 305 meters (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor.
Inquiries: sale@etowonauto.com
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Can Legacy GE 90-70 PLCs Integrate with Modern DCS Systems?
GE Series 90-70 PLC modules remain critical for aging industrial control systems, and redundant hardware configu...
-
What Makes the Bently Nevada 177230 Ideal for Casing Monitoring?
The Bently Nevada 177230 seismic transmitter delivers reliable casing vibration monitoring for auxiliary rotating mac...
-
Can PLC and DCS Replace Dedicated TSI Protection?
This article examines why critical rotating machinery requires independent safety barriers separate from standard PLC...
-
Can Bently Nevada TSI Prevent Turbine Trips in Automation?
This technical article examines why standard PLC and DCS process monitoring fails to detect early-stage rotating mach...
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...