Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:330103-00-08-10-02-00
Bently Nevada 3300 XL 8mm M10x1 330103-00-08-10-02-00
Manufacturer: Bently Nevada
Product No.: 330103-00-08-10-02-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Bently Nevada 330103-00-08-10-02-00 8mm Proximity Probe
Bently Nevada 330103-00-08-10-02-00 | 3300 XL 8mm Proximity Probe, M10x1 metric thread, without armor. Provides 7.87 V/mm (200 mV/mil) output over a 2 mm (80 mils) linear range. Engineered for radial vibration, axial position, and Keyphasor measurements in turbomachinery, compressors, and pumps. Weight: 323 g/m (11.4 oz).
Key Features
2 mm (80 mils) linear measurement range from 0.25 to 2.3 mm. 7.87 V/mm (200 mV/mil) scale factor. Recommended gap -9 Vdc (approx. 1.27 mm / 50 mils). Patented TipLoc and CableLoc designs provide 330 N (75 lbf) pull strength. Miniature coaxial ClickLoc connector, standard cable (Option 02). PPS probe tip material. AISI 303/304 stainless steel case. M10x1 thread, 15 mm maximum thread engagement. Operating temperature -52°C to +177°C. Weight 323 g/m (11.4 oz).
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 330103-00-08-10-02-00 |
| Product Type | 3300 XL 8mm Probe, M10x1, without armor |
| Overall Case Length (Option 08) | 80 mm |
| Total Length (Option 10) | 1.0 m (3.3 ft) |
| Connector Type (Option 02) | Miniature coaxial ClickLoc, standard cable |
| Agency Approval (Option 00) | Not required |
| Linear Range | 2 mm (80 mils) from 0.25 to 2.3 mm |
| Recommended Gap (Radial Vibration) | -9 Vdc (approx. 1.27 mm / 50 mils) |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) |
| Probe DC Resistance (1.0m) | 7.59 ± 0.50 Ω |
| Field Wiring Length | Max 305 m (1,000 ft), 16-24 AWG shielded triad |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Probe Case Material | AISI 303 or 304 stainless steel |
| Case Thread | M10 x 1 |
| Maximum Thread Engagement | 15 mm |
| Pull Strength | 330 N (75 lbf) |
| Operating Temperature (Standard) | -52°C to +177°C (-62°F to +350°F) |
| Storage Temperature (Standard) | -52°C to +177°C (-62°F to +350°F) |
| Pressure Seal | Viton O-ring |
| Relative Humidity | 93% for 56 days (<3% ASF change) |
| Weight | 323 g/m (11.4 oz) |
Ordering Code Breakdown
330103-00-08-10-02-00
330103 – 3300 XL 8mm Probe, M10x1 thread, without armor.
00 – Unthreaded Length: 0 mm.
08 – Overall Case Length: 80 mm.
10 – Total Length: 1.0 m (3.3 ft).
02 – Miniature coaxial ClickLoc connector, standard cable.
00 – Agency approval not required.
Hazardous Area Approvals
| Intrinsic Safety (ia) | Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga; Class I, Groups A-D; Class II, Groups E-G; Class III |
| Non-Sparking (nA, ec) | Class I, Zone 2: AEx/Ex nA IIC T5...T1 Gc; Class I, Division 2, Groups A-D; Class I, Zone 2: AEx/Ex ec IIC T5...T1 Gc |
Installation Notes
Mount probe using M10x1 metric thread. Maximum thread engagement 15 mm. Set initial gap to -9 Vdc (approx. 1.27 mm / 50 mils) for radial vibration monitoring. Use 3-conductor shielded triad cable for field wiring (16-24 AWG), max length 305 m (1,000 ft). Ensure temperature does not drop below -34°C (-30°F) to prevent pressure seal failure. For hazardous area installation, use intrinsic safety barriers per drawing 141092 or non-incendive circuit per drawing 140979.
Engineering Advantages
M10x1 metric thread simplifies installation in metric-dimensioned machinery. 8mm probe design delivers thicker PPS encapsulation for superior durability. TipLoc and CableLoc technologies prevent common failure modes. 330 N pull strength ensures cable integrity. 2 mm linear range with 7.87 V/mm scale factor provides precise measurement. ATEX/IECEx hazardous area approvals enable installation in Zone 0 and Zone 2 environments.
FAQs
Q1: What is the thread size?
A1: M10 x 1 metric thread, with 15 mm maximum thread engagement.
Q2: What is the recommended gap setting for radial vibration?
A2: -9 Vdc, approximately 1.27 mm (50 mils).
Q3: What hazardous area approvals are available?
A3: Intrinsic safety (ia) for Class I Zone 0, and non-sparking (nA/ec) for Class I Zone 2/Division 2.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...