Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:1769-L32E
Allen-Bradley 1769-L32E CompactLogix 750KB Controller Processor
Manufacturer: Allen-Bradley
Product No.: 1769-L32E
Product Type: Controller Processor
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The 1769-L32E is a reliable, field-proven CompactLogix 5330 controller processor manufactured by Allen-Bradley (Rockwell Automation). Designed as a cost-effective and robust solution for small-to-medium standalone machine control, this Programmable Automation Controller (PAC) features 750 KB of user memory and supports expandable non-volatile storage via industry-standard CompactFlash cards (1784-CF64 or 1784-CF128). It comes equipped with one embedded 10/100 Mbps EtherNet/IP port for high-speed plant network interfacing and one isolated RS-232 serial interface. Weighing 0.91 kg (2.0 lbs), this modular CPU manages up to 16 local 1769 Compact I/O modules across 3 expansion banks, utilizing an external lithium battery to safeguard critical volatile project memory during power cycles.
Core Technical Advantages
Dual Integrated Communication Interfaces
The 1769-L32E features two distinct, native communication ports on its front face. The embedded 10/100 Mbps EtherNet/IP port provides high-speed peer-to-peer interlocking, HMI integration, and distributed I/O control. The secondary RS-232 channel supports DF1, DH-485, and ASCII protocols, enabling direct connections to legacy barcodes, serial modems, or print stations.
Flexible CompactFlash Project Storage
To complement its 750 KB of internal user memory, the processor includes a front-accessible CompactFlash slot. By deploying a 1784-CF64 or 1784-CF128 card, automation engineers can configure automated backup utilities that store alternative project source files, user tags, and system firmware images for quick field retrieval.
Robust High-Vibration Mechanical Build
Engineered to handle tough plant floor setups, the controller is built inside a heavy-duty casing. It features high physical ratings with an operating mechanical shock resistance of up to 30G and continuous vibration protection up to 5G at 500 Hz. This makes it ideal for mounting inside control enclosures on heavy machinery skids or moving transport carriages.
Technical Specifications
| Parameter Category | Specification Details |
|---|---|
| Manufacturer / Brand | Rockwell Automation / Allen-Bradley |
| Product Part Number | 1769-L32E (CompactLogix L32 Series) |
| Internal User Memory | 750 KB RAM (Retained via 1769-BA Lithium Battery) |
| Embedded Ports | 1x EtherNet/IP (10/100 Mbps RJ45) / 1x RS-232 Serial (9-Pin D-Shell) |
| Local I/O Capacity | Up to 16 Modules max distributed across 3 hardware banks |
| Backplane Current Draw | 850 mA maximum evaluated at 5.1VDC (6.5 Watts heat dissipation) |
| Supported Protocol Extensions | EtherNet/IP, DF1 Full/Half Duplex, DH-485, Token Ring ASCII |
| Ambient Temperature Limits | Operating: 0 °C to +60 °C / Storage: -40 °C to +85 °C |
| Physical Base Weight | 0.91 kg (2.0 lbs) net chassis mass |
| Agency Compliance | c-UL-us listed (Class I, Div 2 Groups A, B, C, D), CE, C-Tick |
Installation and Maintenance
DIN Rail Locking and Multi-Bank Layouts
Mount the 1769-L32E processor on a level 35mm DIN rail or secure it directly to the enclosure panel backing using its integrated mounting tabs. When expanding the local bus architecture, this processor can handle a maximum of 16 local 1769 modules across up to 3 separate physical banks. Connect additional banks via 1769 right/left expansion cables, and ensure the module locking bus levers are moved forward completely to bridge the internal connection paths.
1769-BA Lithium Battery Field Replacement
Unlike newer capacitor-backed controllers, the volatile user RAM and Real-Time Clock (RTC) inside the 1769-L32E rely entirely on a replaceable 1769-BA lithium battery. When the front panel 'BATT' indicator flashes red, it indicates that the voltage has dropped below safe limits. To replace the battery without losing your runtime project data, ensure that external system power is applied to the 1769 power supply module before swapping out the battery cell in the front compartment.
IP Address Assignment via BootP/DHCP Utility
Out of the box, the built-in Ethernet/IP port has no factory default IP address. Connect the port to a local network switch and use the Rockwell Automation BootP/DHCP tool to intercept the hardware MAC address. Once identified, assign your required static IP address, subnet mask, and gateway settings, then disable the DHCP parameter to lock the configuration into the processor's permanent memory.
Engineering Advantages
Streamlined Legacy Machine Retrofitting
The combination of an embedded RS-232 serial interface and an Ethernet/IP port makes the 1769-L32E an excellent replacement part for older factory machinery. It allows operators to update control logic while maintaining serial links to legacy operator panels, variable speed drives, or remote telemetry units without adding extra protocol conversion hardware.
Scalable Multi-Bank Expansion Profile
The ability to support up to 16 local I/O modules across 3 expansion banks allows engineering teams to build high-density I/O configurations. This scalability allows you to combine digital, analog, and specialized motion inputs on a single processor rack, minimizing the space required in control panels.
Verified Class I Division 2 Hazardous Safety
Carrying official c-UL-us, CE, and C-Tick compliance stamps, this controller is certified for installation in Class I, Division 2 gas and vapor atmospheres (Groups A, B, C, and D). This rating makes it ideal for water treatment skids, grain elevators, petrochemical pump systems, and midstream infrastructure applications.
Technical FAQs
Q1: What happens if the 1769-L32E loses system power while the BATT LED is red or disconnected?
A1: If the 1769-BA battery is drained or missing during a total power failure, the volatile RAM will lose power and your user project data will be wiped from memory. Upon the next boot, the CPU will clear its configurations and require a fresh project download unless a matching image file was saved to an inserted CompactFlash card.
Q2: Can I use standard consumer CompactFlash cards inside the front memory slot?
A2: While commercial consumer CompactFlash cards may physically fit into the card slot, it is highly recommended to use industrial-grade cards like the 1784-CF64 or 1784-CF128. Industrial cards feature specialized flash management, higher read/write cycle durability, and extended temperature tolerances required to survive plant environments.
Q3: How many total CIP network connections can the 1769-L32E handle at once?
A3: The embedded Ethernet port on the 1769-L32E supports up to 32 total CIP connections. This capacity allows the controller to simultaneously communicate with local HMIs, SCADA monitoring networks, and remote distributed I/O blocks while maintaining consistent communication updates.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvorfor forårsaker PLC-signalforstyrrelser 61 % av nedstengningene?
Tunge produksjonslinjer har 3,2 ganger flere kontrollfeil enn monteringslinjer på grunn av EMI og belastningssjokk. S...
-
Hva er den bekreftede avkastningen på investering i skyautomatisering?
Globale produsenter står overfor spredte anlegg og begrenset vedlikeholdspersonell. Denne artikkelen presenterer veri...
-
Betaler din SMB-prosessfabrikk for mye for industriell automatisering?
Denne artikkelen gir en datadrevet veiledning for små og mellomstore prosessfabrikker om hvordan de kan implementere ...
-
Hvorfor skjedde en nedstengning til en kostnad av 420 000 dollar til tross for CPU-redundans?
Denne artikkelen presenterer 15 år med feltprøvd bevis som viser hvordan skjulte enkeltfeilpunkter forårsaker uplanla...
-
Hvordan reduserte Emerson Edge Control skyavhengigheten med 60 %?
Emerson Edge Control Terminal behandler OT-data på stedet, reduserer forsinkelsen til under 20 ms og filtrerer ut 60 ...
-
Lavkostnads brownfield-automatisering: Er null nedetid mulig?
Denne artikkelen viser hvordan brownfield-anlegg moderniserer eldre PLC- og DCS-systemer ved hjelp av protokoll-gatew...
