Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:1769-ASCII
Allen-Bradley 1769-ASCII | Dual Port ASCII Communication
Manufacturer: Allen-Bradley
Product No.: 1769-ASCII
Product Type: Communication Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The Allen-Bradley 1769-ASCII is a high-performance, dual-port serial communication module designed for the CompactLogix and MicroLogix 1500 platforms. This module enables seamless integration between your PLC and various ASCII-based devices, such as barcode scanners, weigh scales, serial printers, and legacy sensors.
Technical Configuration & Hardware Architecture
The 1769-ASCII features a sophisticated hardware design that prioritizes signal purity and multi-protocol flexibility. It functions as an intelligent I/O module that resides directly on the 1769 backplane.
Dual Isolated Port Topology
Each port on the 1769-ASCII is electronically isolated to 30V continuous, protecting the backplane from ground loops and induced noise common in long-run serial cabling. Port 1 is optimized for RS-232 and RS-422 full-duplex communication, while Port 2 provides robust RS-485 multi-drop capabilities, allowing for versatile field device networking.
Backplane Integration
The module draws its 425mA operating current directly from the 5V DC backplane, simplifying enclosure wiring by eliminating the need for external power supplies. This hardware-level integration ensures that the communication ports are synchronized with the controller's internal clock for precise data time-stamping.
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | 1769-ASCII |
| Number of Ports | 2 Isolated Ports (DB-9 Male) |
| Protocols Supported | RS-232, RS-422, RS-485 |
| Max Baud Rate | 115.2 kbps per port |
| Backplane Current Draw | 425mA @ 5V DC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Isolation Voltage | 30V continuous (710V DC for 1s) |
Installation & Engineering Guide
To ensure optimal performance of the 1769-ASCII, engineers must adhere to specific mechanical and electrical placement rules.
Power Supply Distance Rating
The 1769-ASCII has a power supply distance rating of 4. This means the module must be installed within four slots of the 1769 system power supply to ensure it receives consistent, regulated voltage for its dual-port circuitry.
Cabling and Grounding
For high-reliability data transmission, use high-quality shielded twisted-pair cabling (such as Belden 8761). Proper termination of the cable shield at the chassis ground is essential to minimize the impact of EMI on the ASCII string data, especially when operating at the maximum baud rate of 115.2 kbps.
Engineering Advantages
- Simultaneous Communication: Both ports operate independently, allowing the system to read from a barcode scanner on Port 1 while sending data to a printer on Port 2.
- Protocol Versatility: Native support for multiple RS-standards allows for easy retrofitting of legacy factory equipment into modern ControlLogix-based architectures.
- Rugged Industrial Design: Capable of operating in high-temperature environments (up to 60°C) without the need for active cooling, provided that the 50mm clearance rule is followed.
Technical FAQs
Q1: Does the 1769-ASCII support Modbus RTU?
A1: While the module is hardware-capable of RS-485, it is primarily designed for raw ASCII string communication. Implementing Modbus RTU requires manual ladder logic programming to handle the Modbus frame and CRC checks.
Q2: Can I mix RS-232 and RS-485 on the same module?
A2: Yes. The 1769-ASCII ports are independent. You can configure Port 1 for RS-232 communication with a PC and Port 2 for an RS-485 network of sensors simultaneously.
Q3: Is external power required for the serial signal?
A3: No. The module generates the necessary signal voltages internally from the 5V backplane power. However, the connected device must provide its own power source for its communication interface.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Hvordan optimaliserer full livssyklusforvaltning PLC- og DCS-ressurser?
Tradisjonell industriell eiendelsforvaltning er avhengig av manuell logging og reaktiv feilsøking, noe som fører til ...
-
Kan en integrert reservedelkjede redusere nedetiden?
Uplanlagte utstyrsfeil koster kinesiske fabrikker ¥636 000 per time. Tradisjonell grenseoverskridende reservedelsinnk...
-
Hvorfor mislykkes 30 % av automatiseringsoppgraderinger på grunn av integrasjonsmangler?
Denne tekniske artikkelen forklarer hvordan digital-intelligent fusjon overkommer fragmenterte verkstedsoperasjoner v...
-
Hvorfor stoler tunge industrier på GE Fanuc PLC- og DCS-systemer?
Denne artikkelen undersøker hvordan GE Fanuc-kjernekomponenter løser pålitelighetsproblemer i tungbelastet fabrikkaut...
-
Hvordan forutsier Bently Nevada feil 180 dager i forveien?
Standard PLC- og DCS-systemer overser ofte tidlige vibrasjonsavvik i roterende maskineri, noe som fører til 68 % av p...
-
Hvordan eliminerer ABB Omni-Measurement blinde soner i prosessikkerhet?
ABB Omni-Measurement lukker blinde soner i prosessikkerhet ved hjelp av prediktiv analyse og kryssvalidert sensortekn...
