Gå videre til innholdet
Automatiseringsdeler, global levering
Hopp til produktinformasjon
1 av 3

SKU:1756-L65

Allen-Bradley 1756-L65 ControlLogix 5565 Processor 32MB Memory

På lager (26 enheter), klar til å sendes
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-L65

  • Product Type: Processor Controller

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 350g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 dagers returrett · 12 måneders garanti
  • Rask levering
  • 24/7 kundestøtte
  • Kvalitetssikring

Beskrivelse

Product Overview

The Allen-Bradley 1756-L65 is a high-capacity, single-slot PLC processor belonging to the powerful Logix5565 controller line. Engineered to anchor heavy industrial applications, it features an expansive 32 Mbytes of volatile user program memory and a dedicated 478 Kbytes of high-speed I/O memory. Designed for flexible system scaling, the 1756-L65 supports a massive total capacity of up to 128,000 I/O points (including up to 4,000 analog points) and executes up to 32 independent multi-tasking routines simultaneously. Weighing 0.35 kg (0.77 lbs), this advanced controller slots directly into any standard Allen-Bradley ControlLogix chassis to deliver deterministic processing across massive automated plant infrastructures.

Core Technical Advantages

  • Massive 32MB User Memory Matrix: Provides ample room for large user logic code, extensive data logging structures, and advanced mathematical scripting blocks, eliminating the need to segment complex programs.
  • True Multitasking Logic Engine: Handles 32 tasks simultaneously (1 continuous task and up to 31 periodic or event-driven tasks) to easily prioritize time-critical machine motions over background calculations.
  • Industrial Toughness & Isolation: Tested for 720 VDC structural isolation, 30G operational shock waves, and continuous 2.0G plant floor vibrations across a 0 to 60 degrees Celsius thermal window.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer Allen-Bradley / Rockwell Automation (ControlLogix Series)
Model Part Number 1756-L65 (Logix5565 Series)
Gross Weight 0.35 kg (0.77 lbs)
User Program Memory 32 Megabytes volatile RAM storage matrix
Dedicated I/O Memory 478 Kilobytes fast buffer configuration
Non-Volatile Memory Slot Supports up to 128MB CompactFlash storage card (1784-CF128)
Total System I/O Capacity 128,000 total discrete lines / 4,000 analog words max
Integrated Interfaces 1 Built-in RS-232 serial link port (DF1 / DH-489 channels)
Total Supported Connections Up to 250 logical communications paths
Backplane Slot Allocation Single-slot standard width format
Backplane Current Demands 1200 mA at 5.1 VDC bus lines / 14 mA at 24 VDC potential
Power & Thermal Dissipation 3.5 Watts total consumption / 11.9 BTU/hour thermal output
Battery Model Reference 1756-BA2 replaceable lithium battery pack

Installation & Engineering Guide

  • Chassis Mounting & Layout: The 0.35 kg CPU module can be hot-swapped or cold-inserted into any slot position within a standard ControlLogix chassis (such as the 1756-A4, A7, A10, A13, or A17 frameworks). Line up the circuit edges with the chassis guide tracks, pushing firmly back until both the upper and lower plastic retaining tabs snap securely onto the metal structure to support the unit against plant floor vibrations.
  • Non-Volatile Flash Configuration: To protect your 32MB application code against power failures, insert a compatible CompactFlash card into the front memory slot. Through Studio 5000, engineers can configure the processor to boot up automatically from the card during power-on, ensuring zero runtime data loss.
  • Network Architecture Integration: While the 1756-L65 includes a native RS-232 serial port for diagnostic laptops or legacy networks, large-scale plant distributions should run alongside dedicated communication bridge cards (like the 1756-EN2T for EtherNet/IP, 1756-CN2 for ControlNet, or 1756-DNB for DeviceNet links).

Technical FAQs

Q1: What happens if the onboard battery fails on the 1756-L65 processor?
A1: The 1756-L65 utilizes volatile RAM to maintain runtime logic. If the 1756-BA2 lithium battery dies while the chassis loses power, the volatile 32MB memory will drop its program. To prevent this downtime, we highly recommend storing a permanent copy of your application logic on an optional CompactFlash card.

Q2: Can the 1756-L65 communicate directly over EtherNet/IP out of the box?
A2: The processor only features a built-in RS-232 serial port. To link the 1756-L65 to an EtherNet/IP network, you must add an adjacent Ethernet communication module, such as the 1756-EN2T or 1756-ENBT, into the same ControlLogix backplane chassis.

Q3: Does the 0.35 kg mechanical weight place limits on where I can install the card inside the chassis?
A3: Not at all. The compact 0.35 kg balance is distributed across a single-slot standard width footprint. Thanks to its native direct backplane connection system, it operates with full efficiency in any open slot location of your rack, though slot 0 is the common engineering standard for the main CPU.

Skalar (V/f)

Vektor

AC-drevet

  • Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
  • Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
  • Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
  • Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
  • Følg produsentens instruksjoner og beste praksis under installasjon.

Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.

Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.

For mer informasjon, vennligst se vår Frakt- og returpolicy.

Vis alle detaljer

SIKRE PÅLITELIG MASKINYTELSE

Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.