Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:DSTC404
ABB 57520001-DS DSTC404 Powered Terminator for DSTC 452
Manufacturer: ABB
Product No.: DSTC404
Product Type: Powered Terminator
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 20g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The ABB DSTC 404 (Part Number: 57520001-DS) is a specialized powered termination module designed for the ABB Advant Master Process Control and DCS series. Engineered as a dedicated bus terminator, the DSTC 404 is used in conjunction with the DSTC 452 modem to bridge communications between the Sub-System Bus (SDB) and the Local Bus (LDB). It provides essential electrical termination on the SDB side—especially in architecture layouts utilizing "intermediate" modem connections—to maintain signal integrity, suppress signal reflections, and ensure high-speed control network stability. Weighing an ultra-lightweight 0.02 kg (0.044 lbs), its compact slimline body easily integrates into crowded cabinet spaces.
Core Technical Advantages
- Critical Network Termination: Eliminates bus noise, signal bounce, and cross-talk across SDB-to-LDB modem links, securing predictable automation communication.
- Ultra-Light Compact Profile: With a net weight of just 0.02 kg and slim dimensions (260 mm x 120 mm x 10 mm), it minimizes physical strain on rail mountings and maximizes cabinet space efficiency.
- Active 24V DC Power Support: Powered directly via standard industrial 24V DC supplies (±10%), ensuring steady signal stabilization under active plant operating conditions.
- Flame-Retardant Construction: Built with a high-grade polycarbonate housing rated for operating environments from -20°C to +60°C.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | ABB Automation |
| ABB Type Designation | DSTC 404 |
| Product ID / Part Number | 57520001-DS |
| Gross Weight | 0.02 kg (0.044 lbs) |
| Catalog Description | DSTC 404 Terminator, powered |
| System Compatibility | Advant Master / Advant OCS / S400 I/O / DSTC 452 Modems |
| Operating Voltage | 24V DC ± 10% |
| Operating Temperature Range | -20°C to +60°C (-4°F to +140°F) |
| Dimensions (L x W x H) | 260 mm x 120 mm x 10 mm |
| Enclosure Housing Material | Flame-retardant polycarbonate |
| Certifications & Compliance | CE Certified, RoHS Compliant |
| Customs Tariff (HS Code) | 85389091 |
Installation & Engineering Guide
- Application Layout: One 0.02 kg DSTC 404 powered terminator is required on the Sub-System Bus (SDB) side per active DSTC 452 modem connection. Ensure it is selected whenever the modem functions in an "intermediate" configuration along the line.
- Power Supply Wiring: Wire the unit to a regulated 24V DC industrial power rail. Always double-check source polarity prior to powering up to prevent potential protection circuit trips.
- Cabinet Environmental Management: Mount the lightweight 0.02 kg module flat inside the enclosure, ensuring adequate airflow to keep operating temperatures strictly within the -20°C to +60°C rating.
Technical FAQs
Q1: Why is a powered terminator required instead of a passive resistor line?
A1: The DSTC 404 actively maintains signal voltage levels and impedes reflection across complex Advant Master bus topologies, providing superior noise immunity compared to passive termination in noisy industrial electromagnetic environments.
Q2: Which ABB modem requires the DSTC 404 terminator?
A2: The DSTC 404 is primarily used alongside the ABB DSTC 452 modem for connecting Sub-System Bus (SDB) and Local Bus (LDB) networks.
Q3: How does the ultra-light 0.02 kg design benefit installation in complex control cabinets?
A3: At just 0.02 kg with a 10 mm thin profile, it imposes practically zero mechanical load on cabinet mounting structures, making it extremely easy to place in tight cable ducts or high-density rack configurations without thermal or structural concerns.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How to Solve PLC and DCS Faults in Industrial Automation?
Unplanned downtime in manufacturing is frequently traced to failures in PLC, DCS, and TSI systems, costing medium-siz...
-
How Does ABB System 800xA Enable Cost-Effective DCS Modernization?
This technical article examines a hybrid multi-brand DCS retrofit strategy centered on ABB System 800xA for petrochem...
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
