Gå videre til innholdet
Automatiseringsdeler, global levering
Hopp til produktinformasjon
1 av 3

SKU:8440-1935

8440-1935 Woodward easYgen-3500 Sheet Metal Chassis CPU

På lager (11 enheter), klar til å sendes
  • Manufacturer: Woodward

  • Product No.: 8440-1935

  • Product Type: Operator Interface

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1850g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 dagers returrett · 12 måneders garanti
  • Rask levering
  • 24/7 kundestøtte
  • Kvalitetssikring

Beskrivelse

Product Overview

The 8440-1935 (alternatively designated as the easYgen-3500-1-P1) is an advanced genset controller from Woodward's easYgen-3000 series. Housed in a durable sheet metal chassis designed for cabinet installation, this unit features integrated generator group breaker control. Weighing approximately 4.08 lbs (1,850 g) with front panel dimensions of 282W x 216H x 96D mm, it delivers high-precision power management with 16-bit resolution and an Accuracy Class of 0.5.

Core Technical Advantages

  • High-Precision Measurement: Engineered to Accuracy Class 0.5 with 16-bit resolution and a wide setting range from 1 to 32,000 A.
  • Integrated Breaker Control: Equipped with built-in generator group breaker control for seamless synchronization and switching.
  • Isolated Discrete Inputs: Features robust isolated discrete input channels to protect internal circuitry from field electrical noise.
  • Rugged Sheet Metal Build: Sturdy 1,850 g chassis built to withstand harsh industrial generator control environments.

Technical Specifications

Parameter Specification Details
Manufacturer & Series Woodward Inc. / easYgen-3000 Series
Part Number / Model 8440-1935 (easYgen-3500-1-P1)
Accuracy Class & Resolution Accuracy Class 0.5; 16-Bit Resolution
Current Setting Range 1 to 32,000 A
Discrete Inputs Isolated Discrete Inputs
Chassis & Dimensions Sheet Metal Chassis; 282W x 216H x 96D mm
Net Weight Approx. 1,850 g (4.08 lbs)
Power Factor Circuits Supports Capacitive, Resistive (Unity 1.00), and Inductive Circuits

Industrial Solutions

  • Standby & Prime Power Generators: Manages automatic start/stop, synchronization, and breaker control for diesel and gas generator sets.
  • Multi-Gen Paralleling Systems: Coordinates load sharing and power factor regulation across complex multi-generator installations.
  • Industrial Power Management: Provides reliable monitoring and protection in industrial switchgear and utility backup panels.

Wiring & Installation

Cabinet Mounting & Chassis Grounding

Install the controller inside a protective industrial cabinet using the 282W x 216H x 96D mm cutout profile. Do not connect wires directly to the protective earth terminal on the controller body; route any necessary ground connections exclusively through the designated bottom connector.

Current Transformer Safety Precaution

Always ensure that current transformers (CTs) are properly short-circuited before disconnecting wiring from the controller. Failing to short-circuit CTs during disconnection can result in hazardous high voltages, severe personal injury, or death.

Power Factor Configuration

Configure power factor parameters based on your system load type—capacitive, purely resistive (targeting unity 1.00 where voltage and current waveforms are in step), or inductive.

Engineering Advantages

  • Advanced Power Factor Management: Accurately calculates real-to-apparent power ratios across resistive, inductive, and capacitive circuit profiles.
  • Robust Isolation: Isolated discrete inputs safeguard internal processing components from heavy electrical transients.
  • Flexible Switchgear Integration: Built-in breaker control logic streamlines synchronization architecture in generator control panels.

Technical FAQs

Q1: What is the model designation and accuracy class of the 8440-1935?
A1: It is also known as the easYgen-3500-1-P1 and features an Accuracy Class of 0.5 with 16-bit resolution.

Q2: What safety precaution is critical when disconnecting current transformers?
A2: You must short-circuit the current transformer before disconnection to prevent severe injury or death from high voltage.

Q3: What are the physical dimensions and weight of this controller?
A3: Dimensions are 282W x 216H x 96D mm, with a net weight of approximately 1,850 g (4.08 lbs).

Skalar (V/f)

Vektor

AC-drevet

  • Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
  • Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
  • Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
  • Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
  • Følg produsentens instruksjoner og beste praksis under installasjon.

Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.

Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.

For mer informasjon, vennligst se vår Frakt- og returpolicy.

Vis alle detaljer

SIKRE PÅLITELIG MASKINYTELSE

Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.