Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:3500/65-01-00
3500/65-01-00 Bently Nevada Temperature Module for 3500 Rack
Manufacturer: Bently Nevada
Product No.: 3500/65-01-00
Product Type: Temperature Monitor
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The 3500/65-01-00 145988-02 is a 16-channel temperature monitor for critical machinery. It accepts RTD and isolated-tip TC inputs, delivering precise temperature measurement for turbines and compressors. Designed for the 3500 rack, it ensures reliable thermal monitoring in harsh industrial environments.
Technical Configuration
I/O Module Type: 01 – Internal Terminations
The 01 suffix designates an RTD/Isolated Tip TC module with internal terminations. This eliminates external termination blocks, reducing wiring complexity. Supports 3-wire/4-wire RTDs (Pt100, Ni120, Cu10) and TC types E, J, K, T with built-in cold junction compensation.
Agency Approval: 00 – None
Standard version with no additional agency certifications. Complies with FCC, EMC (2014/30/EU), LV (2014/35/EU), and RoHS (2011/65/EU). Meets ABS and DNV GL marine rules without special approvals.
Technical Specifications
| Parameter | Specification |
|---|---|
| Input Channels | 1 to 16 RTD or isolated-tip TC |
| Input Impedance | >1 MΩ per lead |
| RTD Types | 100Ω Pt (α=0.00385 / 0.00392), 120Ω Ni, 10Ω Cu |
| TC Types | E, J, K, T |
| RTD Excitation | 913 ±7 µA @ 25°C |
| Resolution | 1°C or 1°F |
| Accuracy (Internal Termination) | ±3°C at +25°C (±5.4°F) |
| Cold Junction Compensation | ±2°C at +25°C (±3.6°F) |
| Alarm Setpoints | 0–100% full-scale, under & over |
| Alarm Delays | Alert: 1–60s (1s steps); Danger: 1–60s (0.5s steps) |
| Power Consumption | 3 W nominal |
| Operating Temperature | -30°C to +65°C (-22°F to +150°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Dimensions (H x W x D) | 241.3 mm x 24.4 mm x 241.8 mm |
| Weight | 0.91 kg (2.0 lbs) |
| Rack Space | 1 full-height front slot |
Installation & Maintenance
Wiring & Termination
Internal termination eliminates external blocks. Use shielded twisted-pair cables (max 20Ω per lead for RTDs). Keep TC wires away from high-voltage cables and maintain a minimum bending radius of 10x cable diameter.
Configuration
Configure via 3500 Configuration Software (v3.85+). Set full-scale ranges, alarms, and delays per channel. No manual calibration required. Requires 3500/22 Firmware Rev 1.50+ and 3500/93 Rev 2.02+ for proper communication.
Engineering Advantages
Industrial Durability
Operates from -30°C to +65°C and stores at -40°C to +85°C. Galvanically isolated inputs resist ground loops and noise in power plants and process industries.
TSI Integration
Fully compatible with Bently Nevada's 3500 TSI ecosystem. Real-time temperature data acquisition with the same reliability as vibration monitoring modules.
Precision Alarms
Independent under/over setpoints per channel. Accuracy within 0.13% of desired value. Programmable delays prevent nuisance trips during transients.
Technical FAQs
Q1: Can I use external termination blocks with this module?
A1: No. External blocks are incompatible and will cause an I/O Module Mismatch error (562 ADC Failure). Use only internal terminations.
Q2: Which RTD connection is recommended for best accuracy?
A2: 4-wire RTDs provide the highest accuracy. Order with Modification 179952-01 when purchasing I/O modules for 4-wire use.
Q3: What firmware versions are required?
A3: 3500/22 Firmware Rev 1.50+, 3500/93 Rev 2.02+, 3500/01 Software v3.85+, and System 1 Software Rev 5.2 SP2+. Do not use 3500/02 or 3500/03.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...