Forvandle hjemmet ditt med de nyeste multi-elektroniske løsningene, fra intelligent belysning til stemmestyrte enheter – alle designet for å gjøre livet enklere, tryggere og mer tilkoblet. Optimaliser driften med Bently Nevada 3500 overvåkingssystem, som tilbyr sanntids vibrasjons- og maskintilstandsovervåking for å forhindre feil og maksimere oppetid.
SKU:1734-IJ
1 MHz Encoder Module Allen-Bradley POINT I/O 1734-IJ
Manufacturer: Allen-Bradley
Product No.: 1734-IJ
Product Type: Encoder Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Del
- Rask levering
- 24/7 kundestøtte
- Kvalitetssikring
Beskrivelse
Product Overview
The 1734-IJ is a high-speed incremental encoder module from Allen-Bradley's POINT I/O series. Engineered for precise motion and position feedback, this module features 1 counter channel, an input frequency up to 1 MHz, and a 5 V DC nominal voltage rating. Weighing just 0.08 lbs (approx. 36 g) with compact dimensions of 2.21 x 0.47 x 2.97 inches, it mounts easily on standard DIN rails or panels and pairs with 1734-TB, -TBS, -TB3, or -TB3S wiring bases.
Core Technical Advantages
- High-Frequency Input Capability: Supports selectable input frequencies up to 1 megahertz, 500 kHz, or 250 kHz for fast encoder tracking.
- Comprehensive Data Exchange: Produces 6 or 10 bytes of input data (scanner Rx) and consumes 1 byte of I/O data (scanner Tx) with a 24-bit binary frequency range up to 16,777,215.
- Unique Status Indicators: Features 5 diagnostic LEDs, including flashing yellow status indicators for A, B, and Z inputs when toggling on and off.
- Self-Powered POINTbus Operation: Draws a maximum POINTbus current of 160 mA without requiring any additional external DC power supply.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Brand | Allen-Bradley / Rockwell Automation |
| Catalog Number / Series | 1734-IJ / POINT I/O Series (UPC: 10612598269140) |
| Module Type & Counters | Incremental Encoder Module (1 Counter Channel) |
| Input Frequency Options | 1 MHz, 500 kHz, or 250 kHz |
| Nominal Voltage & Current | 5 V DC nominal; Input current: 19.1 mA @ 5V, 25.7 mA @ 6V |
| Isolation & Dissipation | 50 Volts Continuous Isolation; 1.1 W Power / 3.75 BTU/hr Thermal |
| Physical Dimensions & Mass | 2.21 x 0.47 x 2.97 in; Net Weight: 0.08 lbs (0.036 kg) |
| Operating Environment | -4 to 131 °F (-20 to 55 °C); 5% to 95% non-condensing humidity |
| Compatible Wiring Bases | 1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S (Keyswitch Position 2) |
Industrial Solutions
- Conveyor & Material Handling: Tracks incremental encoder pulses for precise speed and distance positioning on automated lines.
- CNC & Machine Tool Feedbacks: Connects directly to rotary encoders to monitor spindle rotation and axis travel.
- Packaging Machinery: Delivers high-speed pulse counting for registration and web tension control applications.
- Distributed I/O Architecture: Integrates seamlessly into modular POINT I/O drops across complex automation cells.
Wiring & Installation
Terminal Base Preparation
Mount the appropriate 1734 wiring base (1734-TB, -TBS, -TB3, or -TB3S) onto a standard DIN rail or panel. Ensure the keyswitch is set to position 2 to match the 1734-IJ module mechanical keying.
Conductor Termination
Connect encoder signal lines (A return, B return, Z return) using solid or stranded copper wire sized between 22 and 14 AWG. No external DC power supply is required for module operation.
Module Insertion
Align the 1734-IJ module with the wired terminal base and push firmly until it locks securely into place, engaging the POINTbus backplane connectors.
Status LED Verification
Apply system power and verify that the module and network status indicators glow green. Confirm encoder operation by observing the flashing yellow status lights on inputs A, B, and Z.
Engineering Advantages
- Ultra-Compact Footprint: Space-saving 0.47-inch width minimizes panel estate usage in high-density I/O enclosures.
- Robust Shock & Vibration Rating: Built to withstand 30 g operating shock and 5 g vibration at 10 to 500 Hz in demanding industrial plants.
- Real-Time Pulse Visibility: Toggling yellow LED indicators provide instant visual verification of active encoder signals during troubleshooting.
Technical FAQs
Q1: What wiring bases are compatible with the 1734-IJ module?
A1: Compatible with 1734-TB, 1734-TBS, 1734-TB3, and 1734-TB3S wiring bases.
Q2: Does the 1734-IJ require an external power supply?
A2: No. It is powered directly via the POINTbus backplane (max current 160 mA).
Q3: What is the physical weight and maximum input frequency?
A3: The module weighs 0.08 lbs and supports input frequencies up to 1 MHz.
Ytterligere spesifikasjoner
Skalar (V/f)
Vektor
AC-drevet
Kjøpsveiledning
- Bekreft nøyaktig modell, delenummer og spesifikasjoner før bestilling.
- Sørg for kompatibilitet med ditt nåværende maskineri eller kontrollsystemer.
- Ta kontakt via sale@etowonauto.com eller +8617859788089 for teknisk assistanse.
- Gå gjennom leveringsalternativer, leveringstider og fraktkrav.
- Følg produsentens instruksjoner og beste praksis under installasjon.
Frakt og retur
Varer på lager sendes vanligvis samme virkedag. For produkter som ikke er på lager for øyeblikket, kan leveringstiden variere basert på tilgjengelighet. Internasjonal frakt er tilgjengelig, og fraktkostnader beregnes ut fra destinasjon, vekt og valgt transportør.
Returer godtas innen 30 dager etter mottak, forutsatt at varene er ubrukte og i original stand. Returfraktkostnader dekkes av kunden. Vennligst kontakt oss før du returnerer en vare for å få returautorisasjon.
For mer informasjon, vennligst se vår Frakt- og returpolicy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Rask levering
Originale deler til industriell automasjon tilgjengelig for rask levering over hele verden.
-
Enkel retur
30 dagers returrett med 12 måneders garanti for pålitelig etterkjøpsbeskyttelse.
-
24/7 støtte
Responsiv profesjonell støtte for å hjelpe med å opprettholde stabile og effektive operasjoner.
-
Ekte og original
100 % autentisk, hentet direkte fra pålitelige produsenter av industriell automasjon.
Teknisk og kjøpsguide
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...