Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:8440-2055
8440-2055 Woodward easYgen-3000 Back Mount Controller
Manufacturer: Woodward
Product No.: 8440-2055
Product Type: Operator Interface
Product Origin: USA
Payment:T/T, Western Union
Weight: 2150g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Woodward 8440-2055 is a high-performance generator set controller from the renowned easYgen-3000 Series, specifically engineered for switchcabinet back-panel mounting. Unlike front-panel mounted units, the 8440-2055 operates without an integrated Human-Machine Interface (HMI); instead, all parameterization, real-time monitoring, and diagnostic operations are executed remotely via PC utilizing Woodward's ToolKit software. Built with a durable sheet metal housing, this unit weighs approximately 2.15 kg (4.74 lbs) and supports both single-genset and complex multi-unit paralleling schemes for up to 32 generators across mains-parallel applications. Operating across four distinct operational modes—Automatic, Manual, Stop, and Test—the 8440-2055 incorporates advanced analog/discrete I/O capabilities and comprehensive power protection features to optimize engine and generator performance.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Woodward |
| Part Number | 8440-2055 |
| Product Line / Series | easYgen-3000 Series (Manual Reference: 37258P) |
| Mounting Configuration | Cabinet Back Panel Mounting (No integrated HMI) |
| Operating Voltage | 12 / 24 VDC Nominal (8 to 40 VDC continuous range) |
| Current Setting Range & Burden | 1 to 32,000 A / Burden < 0.10 VA |
| Relay Outputs & I/O Isolation | Isolated relay outputs; 10 of 12 alarm outputs configurable |
| Speed Input / Frequency | Magnetic / Switching Pickup (50/60 Hz measurement) |
| Operating Temperature Range | -20°C to +70°C (-4°F to +158°F) |
| Overall Enclosure Dimensions | 282 mm W x 216 mm H x 96 mm D (11.1 in x 8.5 in x 3.8 in) |
| Component Net Weight | Approx. 2.15 kg (4.74 lbs) |
Installation & Operation Guidelines
Cabinet Mounting: Fasten the sheet metal module securely onto the rear mounting plate inside the control cabinet. Due to its 2.15 kg net weight, ensure adequate structural support and maintain clearance around the casing to satisfy passive thermal dissipation across its operational range of -4°F to 158°F.
Software Commissioning: Because the 8440-2055 does not feature front-panel buttons or a display screen, connect a PC running Woodward ToolKit via the serial/USB gateway interface. Configure discrete/analog input setpoints, assign the 10 configurable alarm outputs, and establish speed pickup parameters prior to placing the generator into Automatic or Mains Paralleling mode.
Technical FAQs
Q1: How is the module controlled without an HMI?
A1: All parameter configurations, monitoring, and mode selections are managed via PC using ToolKit software.
Q2: What key protection functions are supported?
A2: It monitors generator overload, speed/frequency mismatches, phase shift, and unbalanced load conditions.
Q3: How many units can be paralleled together?
A3: The controller supports load sharing and mains-parallel operation for up to 32 generator units.
Commercial Contact Email: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
