Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:3500/50M-01-00
Bently Nevada 3500/50M-01-00 Tachometer Module | 286566-02
Manufacturer: Bently Nevada
Product No.: 3500/50M-01-00
Product Type: Tachometer Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 820g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Bently Nevada 3500/50M-01-00 286566-02 is a dual-channel tachometer module for 3500 monitoring systems. It measures speed, zero speed, and rotor acceleration on turbines, compressors, and pumps using proximity probes or magnetic pickups.
Technical Configuration
3500/50M – Tachometer Module.
-01 – I/O module with internal terminations.
-00 – No agency approval.
Accepts up to two transducer inputs. Supports 1 to 255 events per revolution, max full scale 99,999 rpm, max input frequency 20 kHz.
Technical Specifications
| Input Signal Range | +10.0 V to -24.0 V |
| Input Impedance | 20 kΩ (standard) / 40 kΩ (TMR) / 7.15 kΩ (Internal Barrier) |
| Transducer Supply | 24 Vdc, 40 mA max per channel |
| Max Input Frequency | 20 kHz |
| Max Full Scale RPM | 99,999 rpm |
| RPM Accuracy (<100 rpm) | ±0.1 rpm |
| RPM Accuracy (100-10,000 rpm) | ±1 rpm |
| RPM Accuracy (10,000-99,999 rpm) | ±0.01% of true speed |
| RPM/Min Accuracy | ±20 rpm/min |
| Recorder Output | +4 to +20 mA, 0 to 600 Ω load |
| Resolution | 0.3662 µA/bit ±0.25% (room temp) |
| Power Consumption | 5.8 W typical |
| Dimensions (HxWxD) | 241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in) |
| Weight | 0.82 kg (1.8 lb) |
| Rack Space | 1 full-height front slot |
Installation Guide
Mount in any full-height front slot of a 3500 rack. For proximity probes, set the Auto Threshold for inputs above 0.0167 Hz. For magnetic pickups, minimum input frequency is 3.3 Hz. Manual threshold adjustable from +9.5 Vdc to -23.5 Vdc with 500 mV peak-to-peak minimum amplitude. Use shielded cables for field wiring.
Engineering Advantages
High accuracy across the full speed range (±0.01% above 10,000 rpm). Dual-channel input with independent recorder outputs. Short-circuit protected buffered transducer outputs on front coaxial connectors. Supports advanced rotor acceleration and zero speed detection with programmable alarm delays (1-60 sec).
Technical FAQs
Q1: What transducers are compatible?
A1: Accepts up to two proximity probe transducers or passive magnetic pickups. For magnetic pickups, the minimum input frequency is 3.3 Hz.
Q2: How to set the trigger threshold?
A2: Use Auto Threshold for signals above 0.0167 Hz (1 rpm at 1 event/rev). Manual threshold adjustable from +9.5 Vdc to -23.5 Vdc with minimum 500 mV peak-to-peak amplitude.
Q3: What are the firmware requirements for integration?
A3: Requires 3500/22M Firmware Rev 1.70, Configuration Software v4.20+, Data Acquisition v2.52+, and 3500/50M Firmware Rev 5.30+. Not compatible with 3500/20 racks.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Migrate ABB PLCs Without Stopping Production?
Aging ABB PLC platforms create rising reliability and spare-part risks for process plants. This article explains wher...
-
How Does Honeywell DCS Modernization Cut Refinery Downtime?
Honeywell DCS modernization helps refineries replace aging control hardware without full shutdowns. It tightens proce...
-
Why Do Hybrid DCS-PLC Systems Cause False Trips?
This article explains how to align Emerson DCS anti-surge control with ABB PLC compressor protection in hybrid ind...
-
How Can Brownfield Upgrades Modernize GE Fanuc DCS Visualization?
Aging GE Fanuc DCS visualization stacks create spare part delays, alarm chaos and unplanned downtime. This article ex...
-
Why Separate Safety PLC from GE Fanuc DCS?
Legacy GE Fanuc DCS platforms often merge process control with emergency trip logic, creating hidden risks durin...
-
How to Calibrate ABB PLC Signals for Emerson DCS Loops?
This article explains how to calibrate ABB PLC analog signals feeding Emerson DCS continuous process loops in hybrid ...