Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:330905-05-08-10-01-00
330905-05-08-10-01-00 Bently Nevada Vibration Probe PTFE
Manufacturer: Bently Nevada
Product No.: 330905-05-08-10-01-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 190g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Bently Nevada 330905-05-08-10-01-00 Proximity Probe
Product Overview
The Bently Nevada 330905-05-08-10-01-00 is a precision proximity probe designed for vibration and position monitoring in industrial rotating machinery. It delivers 200 mV/mil output (±5% tolerance) with ±0.015 mm measurement accuracy and a linear range of 0.08-1.27 mm. The IP67-rated stainless steel housing ensures durability in harsh environments. Weight is 185 g ±5 g.
Specifications
| Parameter | Value |
|---|---|
| Brand | Bently Nevada |
| Model | 330905-05-08-10-01-00 |
| Product Type | Proximity Probe / Vibration Sensor |
| Output Voltage | 200 mV/mil (±5% tolerance) |
| Measurement Accuracy | ±0.015 mm |
| Linear Range | 0.08-1.27 mm |
| Thread Type | M10 x 1 |
| Probe Diameter | 8.0 mm (±0.1 mm) |
| Frequency Response | 0.5 Hz to 12 kHz |
| Operating Temperature | -40 °C to +85 °C |
| Cable Jacket | PTFE, 1.5 m heat-resistant |
| Termination | ClickLoc 3-pin |
| Ingress Protection | IP67 |
| Housing Material | Stainless Steel |
| Cable Bend Radius | ≥25 mm |
| Vibration Limit | 50 g peak |
| MTBF | 5,000+ hours |
| Weight | 185 g ±5 g |
Key Features
- 200 mV/mil output with ±5% tolerance for reliable signal transmission
- ±0.015 mm measurement accuracy for precise position monitoring
- Linear range 0.08-1.27 mm for versatile gap settings
- IP67-rated stainless steel housing for dust and water resistance
- Wide frequency response from 0.5 Hz to 12 kHz
- PTFE cable jacket with 1.5 m length for heat resistance
- ClickLoc 3-pin termination for secure connection
- 5,000+ hours MTBF for long-term reliability
- 50 g peak vibration limit for demanding applications
- Minimum 25 mm cable bend radius for installation flexibility
Installation Notes
Install the probe with the M10 x 1 thread, ensuring proper torque settings. Maintain cable bend radius of at least 25 mm to prevent damage. The 8.0 mm probe diameter provides standard compatibility with Bently Nevada mounting fixtures. For optimal performance, set the gap within the 0.08-1.27 mm linear range.
FAQs
Q1: What is the recommended gap voltage for this probe?
A1: Set the gap voltage per Bently Nevada 3300 XL system guidelines. Typical setting is -10 Vdc at the midpoint of the linear range.
Q2: Is the PTFE cable suitable for high-temperature applications?
A2: Yes. The PTFE jacket provides excellent heat resistance for the 1.5 m cable length, suitable for the -40 °C to +85 °C operating range.
Q3: What is the significance of the 5,000+ hours MTBF?
A3: This indicates high reliability with a mean time between failures exceeding 5,000 hours, reducing unplanned maintenance in critical applications.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...