Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:AAR181-S50
Yokogawa AAR181-S50 RTD Input Module 12 Channels Pt100
Manufacturer: Yokogawa
Product No.: AAR181-S50
Product Type: RTD Input Module
Product Origin: JP
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Yokogawa AAR181-S50 RTD Input Module
The Yokogawa AAR181-S50 is an RTD input module. It provides 12 individually isolated input channels. This module measures Pt100 temperature sensors for process control applications.
Technical Specifications
- Brand Yokogawa
- Model AAR181-S50
- Product Weight 0.2 kg
- Input Channels 12 individually isolated
- Input Type RTD: Pt100 (3-wire)
- Allowable Input Voltage ±5 V
- Withstanding Voltage 1500 VAC for 1 minute
- Input Resistance ≥2 MΩ (Power ON/OFF)
- Accuracy ±120 mΩ (RTD)
- Measurement Current 1 mA (RTD)
- Temperature Drift ±120 mΩ/10°C
- Data Update 1 second (all channels)
- Burn-out Detection Optional (UP/DOWN), 60 seconds
- Current Consumption 450 mA at 5V DC max
- Connection Pressure clamp terminal
Key Features
- 12-Channel Input 12 isolated RTD measurement points
- High Accuracy ±120 mΩ precision for Pt100 sensors
- Safety Isolation 1500 VAC withstand voltage
- Lightweight 0.2 kg compact module design
- Fast Update 1-second scan time for all channels
- Burn-out Detection Optional sensor failure detection
- Low Power 1 mA measurement current per sensor
Installation
- Install in compatible Yokogawa I/O unit
- Connect Pt100 sensors to pressure clamp terminals
- Use proper 3-wire configuration for each channel
- Ensure wiring complies with ±5V input limits
- Configure burn-out detection if required
Packaging
- One AAR181-S50 RTD Input Module
- Shipping weight: 0.5 kg
- Shipped via FedEx UPS DHL
FAQ
How many input channels does this module have?
The AAR181-S50 has 12 individually isolated RTD input channels.
What is the weight of the module?
It weighs 0.2 kg.
What type of RTD sensor does it support?
It supports 3-wire Pt100 resistance temperature detectors (RTDs).
Additional Specifications
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Full-Cycle Data Recording Solve Hidden PLC and DCS Faults?
This article examines how GE full-cycle data recording addresses the critical blind spots in traditional PLC and DCS ...
-
How Can Smart Sensor Maintenance Cut False Alarms by 71%?
This article presents a data-driven approach to gas sensor lifecycle management for hazardous area monitoring instrum...
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...