Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:5437-080
Woodward 5437-080 NetCon Field Terminal Module 24V
Manufacturer: Woodward
Product No.: 5437-080
Product Type: Terminal Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 2500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Technical Specifications
| Manufacturer / Brand | Woodward Inc. |
| Product Series | NetCon 5400 Series Turbine Control Systems |
| Part Number | 5437-080 |
| Product Type | NetCon Field Terminal Module (FTM) / Relay Module |
| Connector Type | Subminiature D-Type 37-Pin Connector |
| Input / Relay Voltage | 24 VDC |
| Display & Controls | 24-Character LED Display | Emergency Stop Button |
| Mounting & Termination | 35 mm DIN Rail Mountable | Cage-Clamp Terminals |
| Physical Dimensions | 14 in x 11 in x 4 in (355.6 mm x 279.4 mm x 101.6 mm) |
| Weight | Approx. 2.5 kg (5.5 lbs) |
Product Overview
The Woodward 5437-080 is a NetCon Field Terminal Module (FTM) designed for NetCon 5400 Series turbine control systems. Measuring 14 x 11 x 4 inches and weighing approximately 2.5 kg (5.5 lbs), this 24 VDC relay module connects field wiring directly to MicroNet and NetCon I/O modules via a subminiature D-type 37-pin connector. It features cage-clamp terminal points, an integrated 24-character LED status display, an Emergency Stop button, EMI shielding, and 35 mm DIN rail mounting capability.
Key Features
- 37-Pin Connector & Cage-Clamp Terminals: Enables secure connection between front I/O modules and external field control wiring.
- Integrated Emergency Stop & Display: Built-in Emergency Stop button and 24-character LED display for local monitoring and safety control.
- Precision Relay Switching: Interfacing low-voltage control electronics with higher-power external electrical circuits safely.
- EMI & Shielding Protection: Designed to provide reliable noise rejection, shield termination, and robust signal integrity in industrial environments.
Installation Essentials
Snap onto 35 mm DIN rail. Secure 37-pin cable, terminate field wiring, and ensure grounding.
Technical FAQs
Q1: What is 5437-080's function?
A1: 24VDC NetCon relay field terminal module with 37-pin plug.
Q2: What is its size and weight?
A2: Dimensions 14x11x4 in, weighs approx. 2.5 kg (5.5 lbs).
Q3: How is field wiring terminated?
A3: Connects via cage-clamp blocks and 37-pin D-sub connectors.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...