Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD040C43A-21
VFD040C43A-21 Delta Drive | 4KW C2000 Series Motor Controller
Manufacturer: Delta
Product No.: VFD040C43A-21
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 2600g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Delta VFD040C43A-21 C2000 Series Variable Frequency Drive
The Delta VFD040C43A-21 is a 5HP variable frequency drive from the C2000 Series. It controls 3-phase AC motor speed for industrial automation systems.
Electrical Specifications
- Brand & Series: Delta C2000 Series
- Model: VFD040C43A-21
- Input Voltage: 460V AC, 3-Phase
- Output Power: 5 HP (4.0 KW)
- Current Rating: 10.5A Heavy Duty / 9A Super Heavy Duty
- Braking Chopper: Built-in for motor deceleration control
- EMC Filter: Not built-in
- DC Reactor: Not built-in
- CANopen Card: Not included
Physical Specifications
- Frame Size: A
- IP Rating: IP20 (indoor use in protected enclosure)
- Dimensions: 6.69" W × 5.12" H × 9.84" D (170mm × 130mm × 250mm)
- Weight: 5.72 lbs (2.6 kg)
Application & Installation
- Controls 5HP/4KW 3-phase AC motors in industrial settings
- Ideal for pumps, fans, conveyors, and machinery speed regulation
- IP20 protection requires installation in a proper enclosure
- Ensure adequate cooling and follow thermal guidelines
- Refer to manual for parameter configuration and wiring
Package & Shipping
- Includes: 1x Delta VFD040C43A-21 Variable Frequency Drive
- Standard factory accessories and documentation
- User manual and installation guide provided
- Shipped via FedEx, UPS, or DHL with secure packaging
Frequently Asked Questions (FAQ)
What motor size can this VFD control?
- The VFD040C43A-21 is rated for 5HP (4KW) 3-phase motors. Always match the VFD rating to your motor's nameplate specifications.
Does this drive include communication options?
- This model does not have a built-in CANopen card. However, it may support other communication protocols via optional cards - check Delta's documentation.
Can I use this VFD for single-phase input?
- No. The VFD040C43A-21 requires a 460V 3-phase power input. Using single-phase power can damage the drive.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
