Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD022EL21A
VFD022EL21A Delta Electronics 11A Single-Phase Micro Drive
Manufacturer: Delta
Product No.: VFD022EL21A
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Delta Electronics VFD022EL21A is a commercial-grade, multi-functional micro AC inverter from the high-reliability VFD-EL series. Engineered to support standard induction motor assets up to 3 Horsepower (2.2 kW), this compact variable frequency drive features a convenient single-phase 230V input line configuration that outputs a balanced 3-phase current rated at 11 Amps. Optimized for tight panel footprints and streamlined installation, it incorporates a built-in digital operating keypad, side-by-side DIN-rail mounting capabilities, and an integrated dynamic braking chopper circuit. Relying on an advanced open-loop V/Hz scalar control module, the VFD022EL21A provides exceptionally smooth speed regulation and energy savings for mechanical fans, water pumps, conveyor systems, and dedicated packaging machines.
Core Technical Advantages
Stable Volts-per-Hertz Scalar Control
Operating on a standard open-loop V/Hz tracking profile, the drive supplies reliable voltage-to-frequency proportional output curves. This makes it an exceptionally efficient option for variable and constant torque loads that do not require complex, encoder-based closed-loop response networks.
Internal Dynamic Braking Chopper
A factory-integrated dynamic braking transistor comes standard on the internal power card. When connected to a compatible external power dissipation resistor, the drive effectively prevents overvoltage faults caused by high-inertia regenerative loads during aggressive deceleration cycles.
Onboard Digital User Interface
The drive features factory-integrated operator controls positioned directly on its front panel. This clear digital setup eliminates the need to source standalone keypads, allowing plant operators to quickly adjust frequency parameters, map digital I/O lines, and review active fault logs.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Electronics |
| Model Number | VFD022EL21A |
| Power Specifications | 3 HP / 2.2 kW (Constant Torque capacity) |
| Main Input Power | 1-Phase, 200V to 240V AC incoming spectrum |
| Output Amperage | 11 Amps maximum continuous output current |
| Peak Output Frequency | 0.1 to 600 Hz customizable operation bounds |
| Mechanical Classification | Frame Size B | IP20 ingress protection rating |
| Chassis Dimensions | 6.85 x 3.94 x 5.35 Inches (H x W x D) |
| Net Weight | 1.4 kg (3.09 lbs) nominal physical weight |
Installation and Maintenance
Frame Size B Spacing Clearances
The Frame B chassis features standard physical constraints of 6.85 x 3.94 x 5.35 inches and carries a net weight of approximately 1.4 kg (3.09 lbs). This compact footprint allows for easy DIN-rail attachment. Ensure you leave adequate open space above and below the cooling heatsinks to allow proper air passage inside the enclosure.
Single-Phase Input Power Termination
The incoming single-phase 200–240 V AC supply utility wires should be terminated exclusively onto the primary L1 and L2 terminals. Do not attach any incoming hot source wires onto terminals U, V, or W, as these are dedicated output vectors for supplying balanced 3-phase current to the induction motor.
Environmental Ingress Considerations
This micro inverter features a stock IP20 open-chassis rating and lacks environmental moisture seals. For machine configurations located in zones exposed to oil residue, conductive metal dust, or water spray, ensure the drive is installed inside a sealed secondary electrical cabinet (NEMA 12 or IP54).
Engineering Advantages
High-Frequency Processing Window
Capable of tracking and maintaining output currents up to a high frequency limit of 600 Hz, the VFD022EL21A easily manages specialized high-speed machinery assets, such as wood woodworking spindles, chemical mixers, and processing separators.
Programmable DC Injection Braking
The integrated DC injection control logic enables developers to apply a stationary DC magnetic field across the motor windings. This function provides holding torque to prevent mechanical drift on ventilation fans or heavily loaded conveyor setups prior to active motor acceleration.
Dense Side-by-Side Installation
The streamlined physical layout of the VFD-EL platform allows for adjacent, high-density side-by-side drive clusters on a single control rail. This layout significantly reduces required cabinet enclosure sizes and associated infrastructure costs.
Technical FAQs
Q1: Can I operate the VFD022EL21A drive by feeding it a standard 3-phase AC input?
A1: No, the VFD022EL21A is engineered exclusively for a single-phase 200–240 V AC input line. The internal rectifier circuit converts this single-phase source to provide a standard 3-phase variable frequency output for 3-phase induction motors.
Q2: What is the primary difference between Delta's VFD-E and VFD-EL drive series?
A2: The VFD-EL family is a cost-effective micro drive line that utilizes V/Hz scalar control alongside a built-in digital operating interface. The VFD-E series is a modular vector micro drive platform that provides open-loop vector tracking and supports plug-in expansion cards.
Q3: Is the dynamic braking resistor pre-installed inside the Frame B chassis?
A3: The unit contains the internal dynamic braking control circuit (chopper), but the heavy-duty power resistor itself is an external accessory. To enable active dynamic braking on high-inertia loads, you must size and install an external braking resistor separately.
Commercial Contact Email: sale@etowonauto.com
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...