Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TC-IAH161
Honeywell TC-IAH161 16-Channel Analog Input Module
Manufacturer: Honeywell
Product No.: TC-IAH161
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 250g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Honeywell TC-IAH161 High Level Analog Module
The Honeywell TC-IAH161 is a sixteen-channel high-level analog input module. It provides precise ±10V signal measurement for industrial applications.
Technical Specifications
- Model: Honeywell TC-IAH161 High Level Analog Module
- Input Channels: 16 isolated analog inputs
- Signal Range: ±10V full scale
- Input Impedance: 1 MΩ
- Channel Bandwidth: 20 Hz (-3dB point)
- Isolation Voltage: 2550V DC tested for 1 second
- Response Time: < 5 ms typical
- Temperature Drift: < 0.1% full scale per °C
- RFI Immunity: < 2.0% error at 10V/m, 27-1000MHz
- Operating Temperature: -20°C to +60°C
- Power Dissipation: 4.1 W maximum
- Connection Terminal: TC-TBCH 36-position terminal block
- Mounting: Panel or DIN rail compatible
- Certifications: CE and UL certified
- Weight: 0.25 kg
Key Features
- Sixteen high-impedance ±10V input channels
- High 2550V DC isolation for safety and noise rejection
- Excellent RFI immunity for electromagnetic environments
- Low temperature drift for stable measurements
- Fast <5ms response time for dynamic signals
FAQ
Q: How many input channels does this module have?
A: The TC-IAH161 provides 16 independent ±10V analog input channels.
Q: What is the input impedance?
A: It has high 1 MΩ input impedance for minimal signal loading.
Q: What isolation rating does it offer?
A: It features 2550V DC isolation tested for 1 second.
Packaging & Shipping
- Honeywell TC-IAH161 analog input module
- TC-TBCH terminal block (sold separately)
- Installation and wiring guide
- Shipped via FedEx, UPS, DHL worldwide
For technical specifications: Contact Technical Support
Additional Specifications
- Black
- DC-powered
- Modular
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...