Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:TSXCTY2C
Schneider TSXCTY2C Modicon Counter Module 2 Channel
Manufacturer: Schneider
Product No.: TSXCTY2C
Product Type: Counter Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric TSXCTY2C Modicon Counter Module
Schneider Electric TSXCTY2C | Measurement and counter module for the Modicon Premium and TSX Micro automation platforms. Provides 2 counter channels supporting incremental encoders, absolute encoders, and 2/3-wire proximity sensors. Counting frequency up to 1 MHz. Current sink auxiliary inputs for preset, enable, and read functions. Weight: 0.34 kg (0.75 lb).
Key Features
2 counter channels. Counting frequency up to 1 MHz. Incremental encoder frequency 500 kHz (x1) and 250 kHz (x4). 1 ms cycle time. Current sink auxiliary inputs (preset, enable, read). Compatible with 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders. 24V DC output with 0.5 A nominal current. Thermal overload and short-circuit protection. Zener diode overvoltage protection. Reverse polarity protection.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXCTY2C |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Measurement and Counter Module |
| Number of Channels | 2 |
| Counting Frequency | 1,000,000 Hz (1 MHz) |
| Incremental Encoder Frequency (x1) | 500 kHz |
| Incremental Encoder Frequency (x4) | 250 kHz |
| Cycle Time | 1 ms |
| Input Logic | Current sink auxiliary input (preset, enable, read) |
| Input Compatibility | 2/3-wire PNP/NPN proximity sensors, incremental encoder (10-30V totem pole, 5V DC RS422), SSI absolute encoder, ABE7CPA11 |
| Input Voltage (Sensors) | 24V, 16 mA |
| Input Voltage (Auxiliary) | 24V, 8 mA |
| Input Voltage (Encoder) | 5V, 18 mA |
| Voltage State 1 (Sensors/Aux) | ≥ 11V |
| Voltage State 1 (Encoder) | ≥ 2.4V |
| Voltage State 0 (Encoder) | ≤ 1.2V |
| Voltage State 0 (Sensors/Aux) | ≤ 5V |
| Input Impedance (Encoder) | > 270 Ω at 2.4V; 400 Ω at Un |
| Input Impedance (Sensors) | 1500 Ω at Un |
| Input Impedance (Auxiliary) | 3400 Ω at Un |
| Response Time (Loss of 24V) | < 2.5 ms |
| Response Time (Return of 24V) | < 10 ms |
| Output Voltage | 24V DC (19-30V limits) |
| Nominal Output Current | 0.5 A |
| Maximum Voltage Drop | < 0.5V at state 1 |
| Maximum Leakage Current | 0.1 mA |
| Switching Time | < 0.250 ms |
| Output Protection | Thermal overload, short-circuit, Zener overvoltage, reverse polarity |
| Power Dissipation | 7-10 W |
| Current Consumption | 15 mA @ 24V DC; 850 mA @ 5V DC |
| Local Signaling | RUN (green), I/O fault (red), ERR (red), 2x CH diagnostics (green) |
| Electrical Connection | 1 HE-10 20-pin connector; 2 SUB-D 15 connectors |
| Net Weight | 0.34 kg (0.75 lb) |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤ 2000 m |
| Protective Treatment | TC |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect sensors and encoders via HE-10 20-pin and SUB-D 15 connectors. Verify input voltage limits for each device type: ≤5.5V for encoder, 19-30V for sensors and auxiliary inputs. Use shielded cable for encoder signals to maintain signal integrity at high counting frequencies. Maintain IP20 enclosure and pollution degree 2 environment. LED indicators aid commissioning and fault diagnosis.
Engineering Advantages
1 MHz counting frequency supports high-speed position and motion applications. Dual channels enable simultaneous measurement of two axes. Wide input compatibility covers proximity sensors, incremental encoders, and SSI absolute encoders in a single module. Integrated thermal overload, short-circuit, overvoltage, and reverse polarity protection safeguard the module. 1 ms cycle time ensures fast response for time-critical control. LED diagnostics simplify troubleshooting.
FAQs
Q1: What is the maximum counting frequency?
A1: 1 MHz, with 500 kHz (x1) and 250 kHz (x4) for incremental encoders.
Q2: What input types are supported?
A2: 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders.
Q3: What output does the module provide?
A3: 24V DC output with 0.5 A nominal current, supporting positive logic DC inputs up to 15 kΩ.
Additional Specifications
- Gray
- Silver
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...
-
How Does Modular Gas Transmitter Cut Maintenance Costs?
The Honeywell Universal Transmitter offers a modular, multi-sensor platform for gas monitoring in hazardous industria...
-
Why Do Bently Nevada TSI Sensors Need Single-Point Grounding?
Poor grounding in Bently Nevada TSI systems creates millivolt-level noise that masks real vibration signals and trigg...
