Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140DDO88500
Schneider Electric 140DDO88500 | 12-Channel Sink Output Module
Manufacturer: Schneider
Product No.: 140DDO88500
Product Type: Adaptor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric 140DDO88500 DC Output Module
The Schneider 140DDO88500 is a 12-point discrete output module for Modicon Quantum. It delivers 24-125V DC negative logic (sink) for industrial control applications.
Core Specifications
- Brand & Model: Schneider Electric 140DDO88500
- Series: Modicon Quantum
- Outputs: 12 discrete, 2 groups of 6
- Logic: Negative logic (sink)
- Voltage: 24…125V DC (19.2…156.2V limits)
Electrical Ratings
- Per Point: ≤0.75 A at 0…40°C
- Per Group: ≤3 A at 0…60°C
- Per Module: ≤6 A at 0…60°C
- Surge Current: 4 A for 1 ms
- Response Time: 1 ms (on/off)
- Switching Frequency: ≤50 Hz
Protection & Isolation
- Short-Circuit: Yes
- Internal Fuse: 4 A per group
- Overvoltage: Varistor per group
- Channel-Bus Isolation: 2500 Vrms DC
- Group-Group Isolation: 1200 Vrms DC
Diagnostics & Power
- Fault LED: Red (overcurrent)
- Status LEDs: 16 green (output status)
- Active LED: Green (bus communication)
- Bus Current: 375 mA (6 on), 650 mA (12 on)
- Power Dissipation: 1 W + (0.77 x all points on)
Environmental
- Operation: 0…60°C (32…140°F)
- Storage: -40…85°C (-40…185°F)
- Humidity: 95% non-condensing
- Altitude: ≤5000 m
- ESD Immunity: 4 kV contact, 8 kV air
Physical & Package
- Weight: 0.45 kg (0.99 lb)
- Package Weight: 515 g (18.2 oz)
- Package Dimensions: 31.2 x 4.5 x 16.3 cm
- Shipping: FedEx, UPS, DHL
Installation
- Power off before installation
- Insert into Quantum backplane
- Connect 24-125V DC supply
- Wire for sink (negative logic)
- Check LED status after power-up
FAQ
What is negative logic (sink)?
Output switches DC common to the load. Designed for sinking input devices.
Can I mix voltages?
No. All outputs share same external DC supply voltage.
What triggers red fault LED?
Overcurrent condition activates per-group protection.
Additional Specifications
- Gray
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...
