Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MTL831B
MTL831B Hazardous Area Analog Transmitter - MTL
Manufacturer: MTL
Product No.: MTL831B
Product Type: Multiplexer Transmitter
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
MTL831B Multiplexer Transmitter for Analog Inputs
The MTL831B from MTL Instruments is a versatile multiplexer transmitter. It processes inputs from multiple sensors in hazardous areas. This device sends serial data to controllers using Modbus communications for efficient system integration.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL831B
- Product Type: Multiplexer Transmitter
- Input Channels: 16 for THC/mV or 15 for RTD
- Input Types: Thermocouples, mV sources (±60mV max), RTDs
- Weight:0.5 kg
- Communication Protocol: Modbus
- Data Highways: Dual redundant configuration
- Hazardous Area Rating: Zone 0, IIC, T4
- Response Time: 1 second per transmitter
Input Configuration & Flexibility
- The transmitter monitors up to 16 thermocouple or millivolt sources
- It can handle up to 15 RTDs with 2-, 3-, or 4-wire configurations
- You can mix thermocouples and RTDs on the same transmitter unit
- All input sources can be located in Zone 0 hazardous areas
- The device accepts potentiometer inputs up to 1kΩ resistance
Environmental Specifications
- Operating Temperature: -20°C to +60°C
- Storage Temperature: -40°C to +80°C
- The transmitter itself is rated for installation in Zone 0 locations
- It maintains intrinsic safety standards in hazardous environments
Electrical Safety Parameters
- Input Circuit Safety: Umax:out = 15V, Imax:out = 16.3mA
- Maximum Output Power: Wmax:out = 60mW
- Data Highway Input: Umax:in = 30V, Imax:in = 300mA
- Input Cable Parameters: Certified for IIC, IIB, and IIA areas
Frequently Asked Questions
-
Can I mix different sensor types on one MTL831B?
Yes, you can combine thermocouples and RTDs on the same transmitter. -
Does this require separate power in hazardous areas?
No, it is loop-powered through the data highway from the receiver. -
What communication protocol does it use?
The transmitter communicates using standard Modbus protocol. -
How many sensors can one transmitter handle?
It supports 16 THC/mV inputs or 15 RTD inputs simultaneously.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How to Solve PLC and DCS Faults in Industrial Automation?
Unplanned downtime in manufacturing is frequently traced to failures in PLC, DCS, and TSI systems, costing medium-siz...
-
How Does ABB System 800xA Enable Cost-Effective DCS Modernization?
This technical article examines a hybrid multi-brand DCS retrofit strategy centered on ABB System 800xA for petrochem...
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
