Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MTL5082
MTL MTL5082 2/3/4-Wire RTD Isolator Module
Manufacturer: MTL
Product No.: MTL5082
Product Type: Isolator Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Introduction
The MTL5082 from MTL operates as a robust interface for resistance temperature devices. This module connects RTDs located in hazardous areas to monitoring systems in safe areas.
Key Features and Benefits
- The MTL5082 supports 2-, 3-, or 4-wire RTD connections
- You can easily select the wiring configuration using top-mounted switches
- It provides complete isolation between hazardous and safe areas
- This module delivers a repeated resistance output from 10Ω to 400Ω
- It features an open-circuit safety drive that upscales to 420Ω
- The unit has a compact and lightweight design of only 110g
Technical Specifications
- Brand: MTL
- Model: MTL5082
- Weight: 110g
- Input Resistance Range: 10Ω to 400Ω
- Output Resistance Range: 10Ω to 400Ω
- RTD Excitation Current: 200μA nominal
- Temperature Drift: ±10mΩ/°C typical
- Response Time: Within 1s to 4% of final value
- Hazardous Area Certification: Zone 0, IIC, T4
- Supply Voltage Range: 20V to 35V DC
- Isolation: 250V AC between all circuits
Installation and Wiring Guide
- Use terminals 1 and 3 for basic RTD input connections
- Terminal 4 provides the return for a 3-wire RTD configuration
- Terminal 5 is for the sense line of a 4-wire RTD
- Connect the safe-area output to terminals 9 and 10 or 11 and 12
- Apply power using terminals 13 (-ve) and 14 (+ve)
- Ensure the wiring matches your selected switch configuration
Frequently Asked Questions
-
What RTD types does this module work with?
The MTL5082 typically works with Pt100 sensors. -
Can I use it with a 2-wire RTD?
Yes, you can select 2-wire mode using the top switches. -
What happens if my sensor wire breaks?
The module drives the output upscale to 420Ω. -
Is the output wiring independent of the input?
Yes, the safe-side output uses 2, 3, or 4 wires freely.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How Can Modern Automation Reduce Power Plant Downtime?
Discover power plant control system upgrade strategies using PLC & DCS. Real case studies, 24/7 support, and expe...
-
How to Extend DCS and PLC Lifespan With Smart Maintenance?
Effective maintenance of DCS and PLC systems is essential for maximizing uptime and efficiency in industrial automati...
-
Why Combine DCS with Edge Controllers in Oil & Gas?
Expert guide on selecting and maintaining PLC and DCS systems for oil & gas automation. Covers environmental fact...
-
How Does PLC-DCS Integration Boost Power Plant Efficiency?
This article explores strategic approaches to integrating PLC and DCS systems in power plants, featuring real-world c...
-
Are Legacy PLCs Putting Your Petrochemical Operations at Risk?
This article explores the critical role of troubleshooting and optimization in maintaining PLC and DCS reliability wi...
-
What Causes DCS Failures in Power Plants and How to Fix Them?
This article provides a comprehensive guide to managing Distributed Control System (DCS) failures in power generation...
