Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:MTL831C
MTL Instruments MTL831C | 16-Channel Analog Transmitter
Manufacturer: MTL
Product No.: MTL831C
Product Type: Analog Transmitter
Product Origin: USA
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The MTL831C Analog Transmitter from MTL Instruments provides intrinsic safety for hazardous area signal conditioning. This robust transmitter handles 16 channels of various analog inputs and transmits data up to 2km via twisted-pair cable. The MTL831C is certified for Zone 0 installations and operates from -40°C to 70°C.
Technical Specifications
- Manufacturer: MTL Instruments
- Model: MTL831C Analog Transmitter
- Input Channels: 16 maximum configuration
- Signal Types: THC, millivolt, 2/3/4-wire RTD, potentiometer
- Transmission Distance: Up to 2km via twisted-pair
- Operating Temperature: -40°C to 70°C
- Hazardous Certification: Zone 0 intrinsically safe
- Cable Requirement: Shielded twisted-pair recommended
System Configuration
- Receiver Compatibility: MTL838C interface unit
- System Capacity: 1-2 transmitters per receiver
- Output Protocol: Modbus serial data via MTL838C
- Power & Signal: Combined over data highway
- Safety Isolation: MTL5553/MTL5053 required
- Mounting: Hazardous area installation
Application Features
- Intrinsic Safety: Zone 0 hazardous area certified
- Signal Conditioning: Multiple input type support
- Long-distance Transmission: 2km range capability
- Status Monitoring: Comprehensive diagnostic data
- Industrial Robustness: Wide temperature operation
Frequently Asked Questions
- How many input channels are supported?
16 channels of various analog input types.
- What is the maximum transmission distance?
Up to 2km using shielded twisted-pair cable.
- Is this suitable for Zone 0 areas?
Yes, certified for intrinsically safe Zone 0 installation.
For pricing and technical support, contact us at sale@etowonauto.com
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...