Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140DAI45300
Modicon Quantum 140DAI45300 48V AC Input Schneider
Manufacturer: Schneider
Product No.: 140DAI45300
Product Type: AC Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The 140DAI45300 is a high-density 48V AC input module. Schneider Electric designed it for Modicon Quantum systems. This module provides 32 input channels for medium-voltage applications. It offers efficient signal monitoring in space-constrained control panels.
Electrical Specifications
- Brand: Schneider Electric
- Model: 140DAI45300
- Type: 48V AC Discrete Input Module
- Input Channels: 32 AC Inputs
- Input Voltage: 48 V AC
- Input Current: 9.8-11.7 mA (47-63 Hz)
- On-State Voltage: 29-56 V AC
- Response Time: 4.9-12.3 ms
System Configuration
- Channel Groups: 4 isolated groups
- Addressing: 2 Input Words Required
- Bus Current: 250 mA
- Power Dissipation: 10.9 W maximum
- Input Impedance: 5600-6800 Ω capacitive
- Isolation: 1780 Vrms (group-to-group & bus)
Physical & Environmental Data
- Module Weight: 0.7 lb (0.3 kg)
- Package Weight: 16.8 oz (475.0 g)
- Operating Temperature: 32°F to 140°F (0°C to 60°C)
- Storage Temperature: -40°F to 185°F (-40°C to 85°C)
- Relative Humidity: 95% (non-condensing)
Certifications & Standards
- FM Class 1 Division 2 Certified
- cUL Certified
- UL 508 Listed
- CSA C22.2 No. 142 Compliant
- CE Marked
Packaging & Shipping
- Package Dimensions: 12.28" × 1.77" × 6.42"
- Package Weight: 16.8 oz (475.0 g)
- Units per Package: 1 Module
- Shipping: FedEx, UPS, DHL
- Country of Origin: China
Frequently Asked Questions
What is the voltage detection range?
- The 140DAI45300 detects 29-56V AC as On-state. It recognizes 0-10V AC as Off-state for reliable 48V system monitoring.
How many input words does this module need?
- This module requires 2 input words for addressing. This accommodates all 32 input channels in the Quantum system configuration.
What are the isolation specifications?
- The module provides 1780 Vrms isolation between groups. Each group also has the same isolation from the backplane bus for safety.
Additional Specifications
- Gray
- White
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can Joint Control Optimization Boost Manufacturing OEE by 20%?
Traditional disconnected PLC and DCS systems cause 10–18% daily idle time between production stages. This article pre...
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...