Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1771-ID
Input Module 6 Point 120V AC/DC | Allen-Bradley 1771-ID
Manufacturer: Allen-Bradley
Product No.: 1771-ID
Product Type: Discrete Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
1771-ID Allen-Bradley PLC 5 Individually Isolated Discrete Input Module – 6 Inputs
The Allen-Bradley 1771-ID is a PLC 5 individually isolated discrete input module with 6 input channels. Operates with a 92-138V AC/DC range and 120V AC/DC voltage category. Weight is 0.45 kg.
Product Information
| Manufacturer | Allen-Bradley |
| Product Line | PLC 5 |
| Part Number | 1771-ID |
| Module Type | Individually Isolated Discrete Input Module |
| Number of Inputs | 6 |
| Voltage Category | 120V AC/DC |
| Field Wiring Arm | 1771-WD |
| Compatible Chassis | 1771 I/O Chassis |
| Keying | Between Pins 4 and 6; Between Pins 28 and 30 |
| UPC | 662468205511 |
| Weight | 0.45 kg (1.00 lbs) |
Input Specifications
| AC Operating Voltage | 92-138V AC |
| DC Operating Voltage | 92-138V DC |
| AC Input Frequency | 47-63 Hz |
| Nominal Input Current | 8 mA at 120V AC / 8 mA at 120V DC |
| AC Signal Delay (On/Off) | 24 ms (±10 ms) |
| DC Signal Delay (On) | 10 ms (±4 ms) |
| DC Signal Delay (Off) | 20 ms (±9 ms) |
| Max AC/DC Off-State Current | 1.7 mA |
Power Specifications
| Backplane Current | 74 mA |
| Power Dissipation | 0.4-4.4 W |
| Thermal Dissipation | 1.3-15.0 BTU/hr |
| Wiring Arm Screw Torque | 7-9 Inch-Pounds |
Features
- 6 individually isolated discrete input channels
- 92-138V AC/DC operating voltage range
- 120V AC/DC voltage category
- AC input frequency 47-63 Hz
- Compatible with 1771 I/O chassis
- 1771-WD field wiring arm for module replacement
- Individual channel isolation for enhanced safety
FAQs
Q1: How many inputs does the 1771-ID provide?
A1: 6 individually isolated discrete input channels.
Q2: What is the operating voltage and signal delay?
A2: 92-138V AC/DC with AC delay of 24 ms (±10 ms), DC on delay of 10 ms (±4 ms), and DC off delay of 20 ms (±9 ms).
Q3: What wiring arm and backplane current are required?
A3: 1771-WD field wiring arm with 74 mA backplane current.
Additional Specifications
- Black
- Green
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...